A-290 CK-MB utilization in the era of troponin-based testing: A foundational analysis for laboratory demand management

Hanwool Cho, Keon Kim, Ben Kang

Observational

Key points

From the paper's conclusion
  • From a laboratory stewardship perspective, reviewing order sets and follow-up testing protocols may help reduce potentially redundant testing, improve resource utilization, and achieve cost savings without compromising clinical safety or diagnostic accuracy.

Abstract

Background Clinical guidelines from the European Society of Cardiology (ESC) and the American Heart Association (AHA) prioritize cardiac troponin (cTn) as the primary biomarker for the evaluation of myocardial injury. Although biomarkers such as creatine kinase myocardial band isoenzyme (CK-MB) are acknowledged to have potential clinical relevance when used in combination with cTn in selected diagnostic contexts, their incremental value beyond cTn is generally considered limited. In particular, cTn has well-established diagnostic and prognostic utility for risk stratification and serial monitoring, whereas the additional role of other biomarkers remains less clearly defined. We evaluated real-world utilization patterns of cTn and CK-MB in both initial diagnostic and follow-up settings. Methods We retrospectively analyzed all cTn (TnT) and CK-MB tests performed between January 2024 and December 2025 at an approximately 800-bed tertiary-care hospital. To assess initial diagnostic practices, only the earliest specimen per patient was included in the first analysis. To evaluate serial testing patterns, patients with repeated measurements (two or more specimens) were analyzed separately. Specimens were categorized as combined testing (TnT + CK-MB), CK-MB-only, or TnT-only. Results A total of 33,631 patients underwent at least one TnT and/or CK-MB measurement. In the initial specimen per patient, combined testing was observed in 29,407 cases (87.4%), CK-MB-only testing in 2,445 cases (7.3%), and TnT-only testing in 1,779 cases (5.3%). Among 12,018 patients with repeated measurements, 53,679 follow-up specimens were analyzed. In this serial-testing cohort, combined testing (TnT + CK-MB) was observed in 37,818 specimens (70.5%), CK-MB-only testing accounted for 13,837 specimens (25.8%), and TnT-only testing represented 2,024 specimens (3.8%). Conclusion These findings highlight a substantial opportunity to better align laboratory utilization with contemporary evidence-based guidelines. Combined testing was overwhelmingly performed at initial evaluation, and CK-MB-only testing was frequently used during serial follow-up, despite the absence of clearly established additional diagnostic or prognostic benefit beyond cTn. While interpretation should consider local reimbursement policies and practice environments, reassessment of current ordering patterns in the era of high-sensitivity cTn appears warranted. From a laboratory stewardship perspective, reviewing order sets and follow-up testing protocols may help reduce potentially redundant testing, improve resource utilization, and achieve cost savings without compromising clinical safety or diagnostic accuracy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers