A-025 The continued value of CKMB in the era of High Sensitivity cardiac Troponins
Alagarraju Muthukumar
Key points
From the paper's conclusion- Our study quantifies these ordering patterns and investigates the departmental rationales for maintaining CKMB within the modern hs-cTn era.
Abstract
Background High-sensitivity cardiac troponin (hs-cTn) is the definitive biomarker for diagnosing acute myocardial infarction, rendering creatine kinase-MB (CKMB) clinically redundant. Despite ADLM/ACC/AHA guidelines and CMS reimbursement cuts for co-ordered tests, CKMB utilization persists in many hospital systems. This continued reliance on an obsolete marker suggests a significant gap between evidence-based standards and real-world clinical practice. Our study quantifies these ordering patterns and investigates the departmental rationales for maintaining CKMB within the modern hs-cTn era. Methods We conducted a 10-year retrospective analysis (2014–2024) of cardiac biomarker orders across a large multicenter healthcare system to quantify concurrent hs-cTn and CKMB utilization. To investigate clinical drivers of guideline non-adherence, we developed and distributed a targeted qualitative survey to caregivers including cardiothoracic surgeons identified as CKMB ordering providers. Statistical trends in ordering frequency were analyzed by department and year, while survey responses were evaluated to identify specific clinical scenarios such as post-CABG monitoring where CKMB is perceived to offer incremental value. Graphpad prism was used in data analysis. Results Between 2014 and 2024, CKMB utilization in the Emergency Department declined to near-zero by 2017, aligning with ADLMAHA/ACC hs-cTn guidelines. Conversely, ICU and CVICU volumes remained high, with CKMB orders nearly equaling hs-cTn. Survey data showed 71% of providers, primarily cardiothoracic surgeons, opposed removing CK-MB from the test menu due to clinical utility. Notably, hs-cTnI levels post-surgery frequently exceeded 60,000 ng/L, reaching a diagnostic "ceiling" that limited trend interpretation. In these cases, the shorter half-life of CK-MB provided clearer kinetic patterns, allowing clinicians to distinguish perioperative myocardial injury from baseline surgical elevation to guide treatment and discharge. Conclusion We find that while hs-cTn has replaced CKMB in the Emergency Department, CKMB remains as a complementary marker in ICU and CVICU settings. Its continued use is driven by the clinical familiarity of the marker and the need for an additional interpretable cardiac marker when hs-cTn is markedly elevated. These findings highlight the importance of recognizing the unique perioperative context in which CKMB may still provide actionable clinical value and the opportunity for targeted educational initiatives to align test utilization with evidence-based guidelines.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-290 CK-MB utilization in the era of troponin-based testing: A foundational analysis for laboratory demand managementClinical Chemistry · 2026
- Cardiac troponin elevations and risk of major adverse cardiovascular events in five non-cardiac diseasesEuropean Heart Journal · 2026
- Relationship between CK-MB and high-sensitivity cardiac troponin after PCI and the impact on the diagnosis of periprocedural myocardial infarction: insights from Multivessel TALENT trialEuropean Heart Journal · 2026
- High-sensitivity troponin and in-hospital mortality in non-ACS cardiac ICU admissions: a 14-year cohortEuropean Heart Journal · 2026
- Ischemia-Modified Albumin and Conventional Cardiac Biomarkers in Myocardial Infarction: A Narrative Review.Cureus · 2026
- A-026 Impact of Chronic Kidney Disease on the Diagnostic Performance of the 0/1-Hour High-Sensitivity Cardiac Troponin T Triage AlgorithmClinical Chemistry · 2026