Clinical Chemistry

A-280 Single Center Evaluation of Alternative Assessment of Performance for Specific Immunology Analytes

Nou Her, Anne Tebo, Melissa Snyder

Key points

From the paper's conclusion
  • Background Alternative assessment of performance (AAP) for specific immunological analytes is challenging due to biological and analytical variability.

Abstract

Background Alternative assessment of performance (AAP) for specific immunological analytes is challenging due to biological and analytical variability. The main objective of this study was to evaluate performance of the laboratory AAP program for effectiveness and gaps. Methods A historical analysis of AAP for fifteen (n=14) specific immunology biomarkers from 2017 – 2021, averaging 64 challenges per year, was performed. The acceptance criteria defined for each analyte were based on the AAP result percentage difference from the target. Testing was categorized by methodology: enzyme-linked immunosorbent assay (ELISA), electrochemiluminescent immunoassay (ECL), fluoroenzyme immunoassay (FEIA) and multiplex immunoassay (MIA). The performance of each analyte was evaluated against established acceptance criteria; AAP failures were categorized based on the failed parameter. A review of each analyte’s inter-precision data was completed to demonstrate the performance of each analyte during initial validation. Following this evaluation, modified acceptance criteria were established, and an assessment of analyte performance for AAP was completed to determine impact. Results Current percent difference acceptability for testing ranged from 20% to 25% of target. AAP success rate was 99%. Major AAP failure categories were identified as AAP material, methodological, AAP evaluation, technical, analytical, or non-identifiable explanation after extensive troubleshooting. Review of each analyte’s inter-precision data varied between 2% to 22%. Following the evaluation, modifications were made to expand the percent difference acceptability from 20% to 30% of target for each analyte depending on their analytical performance. AAP success rate post modification was 98%. Conclusion Analysis of AAP performance pre and post AAP acceptance criteria modification showed no significant increase in AAP failures. Success rate remains stable. Modifications to acceptance criteria were made based on clinical impact of testing and to align with known analytical performance. Expanded acceptance criteria improved flexibility in reviewing of AAP acceptance and allowed for a comprehensive analysis of overall analyte performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers