A-276 Can an initial high-sensitive cardiac troponin T result less than 6 ng/L rule out acute myocardial infarction?
Nesrine Bensaadi, Joseph Scarano, Matthew Elkins, Michel Nasr, Zhimin Tim Cao
Key points
From the paper's conclusion- We analyzed for (1) the frequency of repeated hs-cTnT testing after an initial <6 ng/L result, (2) diagnosis and diagnostic yield of repeat testing, i.e., any subsequent hs-cTnT =6 ng/L and/or a change in final diagnosis attributable to repeat testing, and (3) 30-day major adverse cardiac events (MACE), ascertained by review of in-system for return ED visits, readmissions, discharge summaries,
Abstract
Background High-sensitive cardiac Troponin T (hs-cTnT) was implemented at our institution in early 2025 for rule-in/rule-out acute myocardial infarction (MI) with a cutoff value of 14 ng/L for female and 22 ng/L for male patients. The hs-cTnT analysis was done using Roche e801 analyzer with LOQ of 6 ng/L. Often, primary physicians order repeat tests even when initial hs-cTnT result was <6 ng/L. The objective of this study was to investigate if initial hs-cTnT <6 ng/L rules out acute MI. Methods We identified hs-cTnT results, when additional test(s) was ordered by primary physicians following an initial result of <6 ng/L, from December 2023 to August 2024. The corresponding patient’s information was extracted from the electronic health record (EHR) with removal of patient identity, for demographics, all additional hs-cTnT results, and diagnosis at discharge. We analyzed for (1) the frequency of repeated hs-cTnT testing after an initial <6 ng/L result, (2) diagnosis and diagnostic yield of repeat testing, i.e., any subsequent hs-cTnT =6 ng/L and/or a change in final diagnosis attributable to repeat testing, and (3) 30-day major adverse cardiac events (MACE), ascertained by review of in-system for return ED visits, readmissions, discharge summaries, and problem lists. Thirty-day MACE was analyzed as a composite endpoint, including all-cause death, MI, or coronary revascularization. Results Upon reviewing nearly 27,000 hs-cTnT results reported during December 2023-August 2024, we identified 144 patients (99 women and 45 men) meeting the selection criteria. Their ages were 49.8±11.9 years (median 50, range 21-80). A total of 313 hs-cTnT results were generated for these 144 patients. Of the 144 patients, 134 had two consecutively ordered tests (268 results) and 10 had =3 hs-cTnT orders (45 results); 142 patients had their second hs-cTnT value <6 ng/L, 1 patient had the second hs-cTnT value of 21 ng/L with final diagnosis of angina, and another one patient had four hs-cTnT results (<6 ng/L at initial test, 44 ng/L at 146 min, 87 ng/L at 221 min and 83 ng/L at 340 min after the initial test) with final diagnosis of asthma exacerbation. Time intervals between any of the two tests ordered were 188.6±193.1 min (median of 190.9 min, range 24-1,397 min). Electrocardiograms (n=152) were performed on all 144 patients and showed: (1) 1 patient had ST-segment elevation which was attributed to pericarditis, (2) 11 had T-wave inversion, (3) 40 had old septal infarction, (4) 30 had ST-segment depression, and (4) 62 had no significant abnormality. Thirty-day outcomes after discharge were tracked for 108 of the 144 patients and found no major adverse cardiac events (MACE) recorded. The patient described above with diagnosis of asthma exacerbation at discharge, was diagnosed with an NSTEMI about 2.5 months after discharge. Conclusion We demonstrated that single initial hs-cTnT result of <6 ng/L safely ruled out acute MI in our cohort patients with negative predictive value 100% (95% CI 97.6–100). The additional hs-cTnT tests added no diagnostic value, and instead added extra laboratory costs and possibly indirect cost, e.g., prolonged patient ED or hospital stay.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Rule Out of Myocardial Infarction With a Novel High-Sensitivity Cardiac Troponin T AssayJAMA Cardiology · 2026
- Analytical Performance Evaluation of the Cardiac Troponin T High Sensitivity Gen 6 AssayThe Journal of Applied Laboratory Medicine · 2026
- Optimisation of the single-sample rule-out pathway for acute myocardial infarctionEuropean Heart Journal · 2026
- Validation of the ESC 0/3h-algorithm with a novel high-sensitivity cardiac troponin I assay in patients with suspected myocardial infarctionEuropean Heart Journal · 2026
- Can composite risk scores improve upon single sample rule-out performance in suspected acute coronary syndrome? A preplanned analysis of the MACROS 2 randomised controlled trialEuropean Heart Journal · 2026
- A-006 Diagnostic performance of an investigational high-sensitivity cardiac troponin T and long-T ITC troponin complex assays for acute myocardial infarction in females and malesClinical Chemistry · 2026