Clinical Chemistry

A-266 Improving Laboratory Efficiency and Patient Safety Through Data-Driven Autoverification in Hematology and Coagulation

Fabiano Mattesco, Roberto Ayoub, Ricardo Marques, Sergio Tufik, Claudia Partel

Key points

From the paper's conclusion
  • This study aimed to design and validate a customized AV algorithm for hematology and coagulation workflows operating across 14 hospital units.

Abstract

Background Laboratory automation has significantly advanced in clinical chemistry; however, implementing autoverification (AV) in the Complete Blood Count (CBC), Prothrombin Time (PT) and Activated Partial Thromboplastin Time (aPTT) remains a challenge due to the complex, non-linear nature of hemostasis assays and scarce guidelines. Manual verification of these high-volume, critical-care tests contributes to increased Turnaround Time (TAT) and inter-observer variability. This study aimed to design and validate a customized AV algorithm for hematology and coagulation workflows operating across 14 hospital units. Methods The autoverification algorithms were designed based on CLSI AUTO10-A guidelines and implemented via middleware connected to the Laboratory Information System (LIS). Rules were applied to samples processed on Sysmex CS-2500 and CA-660 series (Siemens Healthineers®) coagulation analyzers, and Abbott Cell-Dyn (Abbott®) / Mindray BC-5380 (Mindray®) hematology systems. For PT and aPTT strictly in seconds, we applied a delta check based on the Reference Change Value (RCV) formula (Z=1.96, 95% CI), using intra-individual coefficient of variation (CVi) from biological variation databases and pooled analytical variation (CVa) from internal QC (quality control). For derived results International Normalized Ration and aPTT Ratio, where RCV is non-linear, we utilized Boolean logic with strict Reference Intervals and critical limit exclusions. In CBC, RCV-based delta checks were applied to Red Blood Cel (RBC) series due to their low biological index of individuality, while leukocyte and platelet parameters used a hybrid approach combining RCV with absolute verification decision limits (VDL) due to higher psychological oscillations to prevent the release of clinically significant changes that might fall within a wide statistical delta. Sample triggering instrumental flags were automatically routed for manual review. For statistical validation, we compared TAT from pre- and post-implementation over a 12-month period. Non-normal distribution of TAT data, the Mann-Whitney U test was employed to determine statistical significance (p<0.05), and Cohen’s d was calculated to quantify the effect size of the operational improvement. Results The analysis encompassed a dataset of over 2 million laboratory examinations. Post-implementation analysis demonstrated a statistically significant reduction in TAT (p<0.001). The median TAT, which more accurately reflects workflow efficiency in right-skewed distributions, showed substantial improvements, with PT decreasing from 80.45 to 70.25 min and aPTT decreasing from 78.47 to 67.98 min, representing reductions of more than ten minutes in both cases. In CBC, the median TAT decreased from 77.2 to 73.8 min, corresponding to a reduction of 3.4 minutes. Furthermore, sustained performance analysis using 2025 data demonstrated robust system stability with autoverification rates reaching 69.6% for aPTT and 59.5% for PT. For CBC, an autoverification rate of 29.8% was maintained, reflecting the algorithm's high sensitivity in appropriately segregating complex hospital cases requiring mandatory slide review. Conclusion The implementation of a biological variation-based autoverification system significantly improved operational efficiency by reducing median TAT and standardizing the review process. The combination of RCV and VDL proved effective in a high-volume hospital setting. This approach successfully balanced the demand for faster result release with reduced manual review while ensuring patient safety through the statistical detection of analytical errors and clinically significant changes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers