From the paper's conclusion
  • Overall, unreportable rates due to preanalytical error for hematology samples across all clinical trials ranged from 2 to 3 %, with rates in the hematology/oncology disease space of approximately 10 %.

Abstract

Background One of the greatest challenges facing the hematology department of any central laboratory is time. From the moment blood is collected from a patient, cells begin to deteriorate and platelets begin to aggregate. In a hospital setting, analysis often occurs within 1-2 hours post collection; validation and stability assessments often use fresh blood. Central labs, however, must have samples shipped to their location and generally are not able to perform analysis until at least 24 hours post collection. These samples are often collected from a variety of different patient sub-populations and potentially exposed to a variety of different preanalytic variables during transit, any one of which could negatively impact cellular integrity. As a result, central labs are often plagued with samples exhibiting hemolysis and platelet clumping due to pre-analytical and ex vivo effects. Therefore, there is an increased need to understand and control the variables affecting preanalytic phase of testing. Methods Internal studies were performed to evaluate the stability of hematological parameters of a whole blood sample over multiple days using different collection tubes. Additionally, participant data, received de-identified as to demographic information, was compiled from over 800 clinical trials conducted from 2020-2025 were evaluated to identify rates of hemolysis, clotting, and platelet clumping. Finally, manual white blood cell (WBC) differential analysis performed on blood smears made fresh from whole blood samples on the day of collection were compared to WBC differential analysis performed by an automated hematology analyzer 1 to 4 days after analysis. Results Internal studies demonstrated all hematological parameters to be stable for up to 4 days in EDTA whole blood samples collected from healthy individuals and stored under well controlled laboratory conditions with percent changes from baseline ranging from -7.6 to 7.7 percent across all parameters, and the most significant variations occurring on WBC differentials and mean platelet volume (Table 1). Notably, platelet counts in 3.2 % sodium citrate whole blood decrease significantly after 4 hours exhibiting a - 48.5 to -36.8 % bias when compared to an EDTA whole blood sample, thus demonstrating the limited utility of using 3.2 % sodium citrate whole blood for clinical trial participants exhibiting EDTA induced pseudothrombocytopenia (EDTA-PTCP). Overall, unreportable rates due to preanalytical error for hematology samples across all clinical trials ranged from 2 to 3 %, with rates in the hematology/oncology disease space of approximately 10 %. Receipt of blood smear increases the reportable rate significantly while decreasing the rate of apparent neutropenia reported due to whole blood deterioration. Conclusion Centralized databases and Standard Operating Procedures (SOPs) make central laboratories an invaluable resource for clinical trials. As more clinical trials begin to move into the hematology/oncology disease space, it is imperative that central laboratories provide adequate support to ensure successful analytical outcomes. Ultimately, rapid receipt of EDTA whole blood in combination with a well-executed blood smear from the local site continues to be best practice for obtaining reliable hematology results.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-253 Performing Hematology Testing at a Central Laboratory: Challenges and Perspective — Science Skim