A-245 Robust Performance of the Quantra® Hemostasis Analyzer in Global Proficiency Testing

Nat Sherwood

Key points

From the paper's conclusion
  • Conclusion This EQA with optimized material composition provided a robust statistical peer-to-peer analysis for proficiency testing participants using the Quantra Hemostasis System method in a clinical laboratory or POC setting.

Abstract

Background Both CLIA and CAP mandate biannual proficiency testing, which assesses the accuracy and reliability of a methodology. Coagulation proficiency testing aims to routinely monitor a diagnostic analytical method via blind sample testing by a trained user with demonstrated competency. Resulting data is then analyzed against a peer group to determine proficiency. Fulfillment of PT quality standards, backed by comprehensive statistical analysis, ensures accurate, reliable methodology directly correlating to patient safety. The required use of whole blood samples in conventional coagulation proficiency testing poses challenges for interpretation of statistical inter-laboratory comparison due to naturally occurring donor-to-donor variation in coagulation characteristics. Methods An External Quality Assessment (EQA) commensurate to regulatory proficiency testing requirements was developed using alternative, controlled test materials to enable a more robust, comprehensive statistical analysis across all participants. Lot-specific material was incorporated into the annual assessment, maintaining the tenets of biannual, blind-sampled proficiency testing structure. To ensure the structure satisfied laboratory proficiency testing performance needs, the EQA’s procedure mirrored that of a core device operational element. This EQA design facilitated two metrics of comprehensive statistical analysis not afforded by the conventional method: Youden Plot and Z-Score. These analyses afford quantitative insight into both intra-laboratory execution and comparative inter-laboratory performance. Results Between 126-129 data points were collected for each of the four QPlus Cartridge parameters across 74 global participating sites in 2024. Results for all parameters (CTH, CT, CS, FCS) demonstrated an average coefficient of variation (CV) of 5.5% and CVs as low as 3.7% across all specimen compositions (Table 1). An average Z-Score of 0.008 was achieved across these four parameters by all US 2024 EQA participants. In alignment with published criteria, target values for each parameter were equal to the peer group mean. The peer group surpassed sample size requirements following removal of outliers, and result assessment was successfully executed based on an acceptability range defined by the target value ± three standard deviations. Conclusion This EQA with optimized material composition provided a robust statistical peer-to-peer analysis for proficiency testing participants using the Quantra Hemostasis System method in a clinical laboratory or POC setting. Extensive statistical evaluation yielded high precision outcomes, enabling increased confidence in the Quantra method, the reagent quality of the QPlus Cartridge, and overall user proficiency. The substantial participant volume afforded by a global audience enhanced credibility, and therefore reliability, in the results produced by the Quantra Hemostasis System.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-245 Robust Performance of the Quantra® Hemostasis Analyzer in Global Proficiency Testing — Science Skim