Clinical Chemistry

A-117 Analytical Performance of the Allplex™ HSV-1&2/VZV/MPXV Assay for Detection and Differentiation of HSV-1, HSV-2, VZV, and MPXV from Lesion Swabs

Kevin To, Tamara Johnson, Kyeongjee Cho, Baksun Kim, Hee Cheol Kim

Key points

From the paper's conclusion
  • These comprehensive analytical data support the utility of this multiplex assay for detection of HSV-1, HSV-2, VZV, and MPXV from lesion specimens.

Abstract

Background The Allplex™ HSV-1&2/VZV/MPXV Assay is a multiplex real-time PCR test for simultaneous detection and differentiation of herpes simplex virus types 1 and 2 (HSV-1, HSV-2), varicella-zoster virus (VZV), and mpox virus (MPXV) from lesion swabs. The assay employs dual MPXV detection systems: a pan-MPXV system detecting both Clade I and Clade IIa/b, and a Clade IIa/b-specific system for Clade IIa/b confirmation. This study evaluated comprehensive analytical performance characteristics. Methods Analytical studies assessed limit of detection (LoD) using two representative strains per target across three reagent lots in clinical lesion swab matrix. Inclusivity testing evaluated eight additional viral strains representing temporal and geographical diversity. Cross-reactivity and microbial interference were assessed with 51 microorganisms. Interference testing included 20 endogenous and exogenous substances. Carryover and cross-contamination were evaluated using alternating high-positive (1×106 TCID50/mL) and negative samples in a checkerboard design across multiple instruments. Competitive inhibition assessed detection of each target at 3× LoD in the presence of high concentrations of other targets. Precision and repeatability were evaluated using three instruments, three operators, and three reagent lots over 22 non-consecutive days with 144 replicates per panel member. Reproducibility was assessed across three independent laboratory sites with six operators over five days with 150 replicates per panel member. The Allplex™ HSV-1&2/VZV/MPXV Assay at the time of this abstract submission has not been FDA authorized, cleared or approved. Results Analytical sensitivity limits of detection were: HSV-1 at 111 copies/mL (MacIntyre strain) and 2.7 TCID50/mL (HF strain); HSV-2 at 39 copies/mL (MS strain) and 1.6 TCID50/mL (G strain); VZV at 34 copies/mL (Ellen strain) and 225 copies/mL (82 strain); MPXV-I/II at 7.1 copies/mL (Clade IIb) and 2250 copies/mL (Clade I); MPXV-II at 21 copies/mL (Clade IIb). Inclusivity testing showed that all eight additional viral strains (two HSV-1, two HSV-2, four VZV) achieved 100% detection, demonstrating broad reactivity. No cross-reactivity or microbial interference was observed with any of the 51 microorganisms tested, including closely related herpesviruses, orthopoxviruses, and common skin microbiota. All twenty endogenous and exogenous substances showed no interference at 3× LoD. Carryover and cross-contamination testing with 705 high-positive and 705 negative samples demonstrated 0% cross-contamination (95% CI upper limit: 0.54%). Competitive inhibition testing showed that all targets at 3×LoD were detected with 100% sensitivity (5/5 replicates) in the presence of high-concentration co-targets (=1×105 copies/mL). Precision demonstrated 100% agreement (144/144 replicates) across all conditions with total coefficient of variation =2.0% at 2× LoD and =1.4% at 5x LoD. Multi-site reproducibility demonstrated 100% agreement for positive panels (150 replicates/panel) across 3 sites with total coefficient of variation =2.7% and between-site variability =1.5%. Conclusion The Allplex™ HSV-1&2/VZV/MPXV Assay demonstrated sensitive detection, broad inclusivity across diverse viral strains, excellent specificity with no cross-reactivity or interference, and high precision and reproducibility across multiple testing conditions. These comprehensive analytical data support the utility of this multiplex assay for detection of HSV-1, HSV-2, VZV, and MPXV from lesion specimens.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers