Clinical Chemistry

A-116 Clinical Validation of the Seegene Allplex™ HSV-1&2/VZV/MPXV Multiplex PCR Assay for Detection of Viral Pathogens in Cutaneous and Mucocutaneous Lesion Swab Specimens

Ashley Meyers

Observational · n=516

Key points

From the paper's conclusion
  • Conclusion The Seegene Allplex™ HSV-1&2/VZV/MPXV Assay achieved high concordance with FDA-cleared reference methods or expected results for simultaneous detection and differentiation of HSV-1, VZV, and MPXV from lesion swab specimens in UTM/VTM.

Abstract

Background Rapid and accurate identification of viral etiologies underlying cutaneous and mucocutaneous lesions is essential for guiding therapy, infection control, and public health response. Herpes simplex virus type 1 (HSV-1), herpes simplex virus type 2 (HSV-2), varicella-zoster virus (VZV), and mpox virus (MPXV) can present with overlapping clinical manifestations, requiring molecular differentiation. The Seegene Allplex™ HSV-1&2/VZV/MPXV Assay is a multiplex real-time PCR test that detects and differentiates these four pathogens. The assay incorporates dual MPXV detection systems: a pan-MPXV target designed to detect both Clade I and Clade IIa/b strains, and a Clade IIa/b-specific target for Clade IIa/b confirmation. This study evaluated clinical performance using prospectively collected remnant lesion swab specimens compared to FDA-cleared reference methods. Methods A prospective clinical study was conducted at three CLIA-certified U.S. laboratories from January to August 2025. Enrollment included 516 participants (376 female and 140 male), age range from 18 to >60 years (n=252 aged 18-39, n=130 aged 40-59, n=134 aged =60), and samples from both cutaneous (n=208) and mucocutaneous (n=301) lesion sites. Fresh lesion swab specimens in Universal Transport Media (UTM) or Viral Transport Media (VTM) were tested with the Allplex™ HSV-1&2/VZV/MPXV Assay (not FDA authorized, cleared or approved at the time of this abstract submission) and compared against FDA-cleared NAAT assays for HSV-1, HSV-2, and VZV. Due to low MPXV prevalence, contrived MPXV samples were prepared by spiking a representative MPXV Clade IIb strain into negative lesion swab matrix at 2x and 5x the assay’s limit of detection then randomized, blinded, and tested at Seegene USA using the Seegene Allplex™ HSV-1&2/VZV/MPXV Assay. The results of the contrived study were compared to expected results. Results Comparator agreement results of the Allplex™ HSV-1&2/VZV/MPXV Assay were: HSV-1 PPA 95.8% (95% CI: 88.5-98.6%), NPA 97.1% (95% CI: 95.1-98.3%); HSV-2 PPA 98.8% (95% CI: 93.6-99.8%), NPA 99.3% (95% CI: 98.0-99.8%); VZV PPA 96.3% (95% CI: 87.5-99.0%), NPA 99.8% (95% CI: 98.8-100.0%). Among the 516 specimens tested, 72 were positive for HSV-1, 84 for HSV-2, and 54 for VZV by comparator methods. Seven coinfections were detected, including HSV-1/HSV-2 and HSV-2/VZV combinations, demonstrating the assay's multiplex capability. Performance was consistent across specimen types, demographics, and sites. MPXV contrived sample testing at both low positive (2x LoD, n=25) and moderate positive (5x LoD, n=25) concentrations demonstrated 100% PPA (95% CI: 92.9-100.0%) and 100% NPA (95% CI: 90.1-100.0%) to expected results. Conclusion The Seegene Allplex™ HSV-1&2/VZV/MPXV Assay achieved high concordance with FDA-cleared reference methods or expected results for simultaneous detection and differentiation of HSV-1, VZV, and MPXV from lesion swab specimens in UTM/VTM. In contrast to the current testing paradigm requiring multiple separate assays, the Allplex™ HSV-1&2/VZV/MPXV Assay combines HSV-1, and MPXV detection into a single test.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers