A-078 STI Scout®: Chlamydia and Gonorrhea Molecular ID Testing for Home and Resource Constrained Settings
Martin Kemper, Rochelle Nguyen, Cameron Ball
Key points
From the paper's conclusion- Background Access to high quality Chlamydia (Ct) and Gonorrhea (Ng) molecular testing has been expanding beyond the clinic with the advent of Mail-In testing schemes and at-home test platforms, but more work is needed to lower cost and infrastructure barriers.
Abstract
Background Access to high quality Chlamydia (Ct) and Gonorrhea (Ng) molecular testing has been expanding beyond the clinic with the advent of Mail-In testing schemes and at-home test platforms, but more work is needed to lower cost and infrastructure barriers. STI Scout® aims to achieve this by utilizing minimal sample processing and a small, reusable platform, yielding vastly lower per test-costs. The robust assay chemistry unlocks simple instrumentation, avoids complex microfluidics, and allows utilization of pocket-sized power banks for multiple successive tests. This system addresses many pain points of PoC and OtC molecular testing platforms to greatly improve access and break transmission cycles. Methods Assay Chemistry: STI Scout® is a single pot multiplex fluorescent LAMP test performed on the Scout Hub® or RT-PCR thermocycler. Three primer sets are included, targeting: 1) a synthetic DNA internal process control, 2) N gonorrhoeae porA, and 3) C trachomatis orf8 (cryptic plasmid); each is observed in a distinct fluorescence channel. A custom assay formulation utilizing Bst-XT (New England Biolabs) has been created to avoid sample extraction and minimize amplification failures. Reliability/Selectivity: STI Scout’s® functionality with unextracted specimens was determined using 28 unique penile urine donors and 32 unique vaginal swab donors (Medix Biochemica). Internal process control times to result under 30 min were considered valid (Target: <5% invalids). False positive amplifications were assessed with extended run times (Target: No false positives within our 30 min run time.) Purified gDNA from non-Ng Neisseria spp were used to determine cross amplification risk. Sensitivity: Pooled Urine and Vaginal Swab Eluate were spiked with serially diluted live pathogens (Ng: ATCC 700825, Ct: ATCC VR-348B) to obtain preliminary Limits of Detection (N=6, amplification in <30 min). Pathogen target DNA copy numbers were assessed via qPCR to allow comparison with other competitor platforms. Clinical Sample Testing: Vaginal Swab Eluates confirmed Ct positive, Ng positive, or dual negative by Hologic® Aptima Combo 2, were donated by Johns Hopkins University POCTRN. These samples were evaluated using STI Scout®. Results Reliability:Urine: <2% invalid rate (82/83 replicates valid). Zero no target amplifications within 60 min.VSE: <1% invalid rate (95/96 replicates valid). Zero no target amplifications within 60 min. Selectivity:No amplifications within 60 min with 1e6 GC/reaction N meningitidis, N mucousa, or N lactamica added. Sensitivity (contrived specimens with whole pathogen diluted in pooled donor matrix):Urine: Ng: 636.9 GE/mL-Urine, Ct: 485.3 GE/mL-Urine.Vaginal Swab: Ng: 16.8 GE/mL-Eluate, Ct: 33.26 GE/mL-Eluate. Ct and Ng could be accurately detected in remnant VSE clinical specimens on Scout Hubs®. Conclusion The STI Scout® test is robust and sensitive. The test had few invalids using unextracted clinical specimens from a large variety of different donors and can detect quantities of Chlamydia and Gonorrhoeae with LoDs similar to competitor products such as the Binx io® system. Infection status of clinical samples were accurately determined by STI Scout® on Scout Hubs®. This test and platform are nearing prospective clinical trials to demonstrate real world efficacy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-365 A Rapid Multiplex LAMP Assay for Detection of Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis, and Fluoroquinolone Resistance in Neisseria gonorrhoeae with Translatability Across Benchtop and Point-of-Care PlatformsClinical Chemistry · 2026
- A-104 Compatibility of Copan UBM Transport Medium with Molecular Detection of STI Targets across Different qPCR AssaysClinical Chemistry · 2026
- Field Performance and usability of a novel molecular point-of-care assay for Chlamydia trachomatis and Neisseria gonorrhoeae detection.International journal of STD & AIDS · 2026
- Rapid, low-cost colorimetric capillary-driven immunoassay for screening of bacterial STIs: Chlamydia, syphilis, and gonorrhea.Biosensors & bioelectronics · 2026
- Development and Laboratory Evaluation of a porA-Targeting TaqMan qPCR Assay for Neisseria gonorrhoeae: Clinical Specimen Validation and Molecular Estimation Using Cultured Reference Strains.International journal of molecular sciences · 2026
- Molecular typing and characterisation of antimicrobial resistance determinants of Neisseria gonorrhoeae among symptomatic individuals in the Eastern Cape, South AfricamedRxiv · 2026