A-056 Pre-analytical usability assessment and instructional refinement in UriSponge® self-collection for urine culture

Leah Brown, Ashley Hodge, Lee Goneau

Observational · n=53

Key points

From the paper's conclusion
  • These findings demonstrate functional usability in this study population and highlight the importance of structured human factors evaluation prior to broader patient implementation.

Abstract

Background Midstream urine specimens for culture should be processed within 4 hours or refrigerated to prevent bacterial overgrowth that may compromise diagnostic accuracy. The UriSponge® device contains sodium propionate and potassium sorbate embedded within an applicator sponge designed to preserve urine following immersion. As patient-directed and decentralized collection models expand, usability validation is critical to ensure safe and accurate specimen handling. This study evaluated whether intended users, unfamiliar with the UriSponge device and without prior training on its use, could successfully complete all required self-collection tasks without critical task errors and characterize procedural variability to inform instructional refinement. Methods A single-center usability study was conducted in 53 healthy adult volunteers aged 22–70 years. Participants were employees of a clinical laboratory organization and had no prior exposure or training in the use of the UriSponge device. Educational backgrounds varied (87% college/university; 13% high school or less). After informed consent, participants received a kit containing a urine collection container with simulated urine, UriSponge device, biohazard transport bag, instructions for use, and a post-collection questionnaire. Participants performed the collection procedure while directly observed by trained study staff using a structured observational assessment tool documenting instruction adherence, immersion technique, contamination risk, container sealing, and packaging compliance. Participants completed a survey evaluating ease of use, hygiene perception, clarity of instructions, and overall acceptability. The primary endpoint was completion of all procedural steps without critical task errors. Secondary endpoints included characterization of use variability and identification of instructional refinement opportunities. Results All 53 participants completed the collection procedure and returned specimens for assessment. A single critical task error was observed (2%). Ninety-six percent (51/53) reported having sufficient information to complete the process correctly. Ease-of-use ratings were favorable overall: 42% rated the procedure very easy, 47% easy, and 11% moderate; none rated it difficult or very difficult. Perceived hygiene was rated very or mostly hygienic by 91% of participants, and 91% found instructional illustrations helpful. Eighty-three percent reported holding the sponge in urine for approximately 5 seconds as instructed; 15% immersed for less than 5 seconds and 2% for up to 10 seconds. Observed contamination events were infrequent (4%), with urine droplets occurring in 15% of collections. Observed deviations included failure to review instructions prior to initiation (4%), partial sponge immersion (21%), and inconsistent biohazard bag packaging. Feedback emphasized increasing visual content, reducing text density, simplifying step sequencing, reinforcing the 5-second immersion cue, and clarifying packaging instructions. Conclusion Users were able to successfully complete UriSponge self-collection with a low incidence of critical task errors and minimal contamination risk. Observed procedural variability was primarily related to instructional clarity rather than device function. Survey and observational findings informed targeted refinements to improve container identification, immersion consistency, droplet control, and packaging compliance. These findings demonstrate functional usability in this study population and highlight the importance of structured human factors evaluation prior to broader patient implementation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A-056 Pre-analytical usability assessment and instructional refinement in UriSponge® self-collection for urine culture — Science Skim