A-038 Validation of a Specialized Lipids Panel LDT for Serum Analysis Using the Roche Cobas 8000 c702 Platform
Solomon Taboh, Satya Narla, Nadia Ayala-Lopez, Omolola Durodola, Lawrence Spaid, Christy Armold
Key points
From the paper's conclusion- To address these challenges, Labcorp developed a Specialized Lipids Panel LDT on the Roche Cobas 8000 c702 that integrates precipitation-based HDL-C with ultracentrifugation-derived LDL-C, providing a higher accuracy alternative to conventional lipid measurements.
Abstract
Background HDL-C and LDL-C are key cardiovascular biomarkers, but traditional estimation formulas lose accuracy in high triglyceride and non-fasting states, and direct homogeneous assays remain vulnerable to matrix interferences. Although ultracentrifugation is considered the reference method for LDL-C measurement, its technical complexity and labor-intensive workflow make it impractical for routine clinical use. These limitations are particularly consequential in clinical trials, where precise lipid quantification is critical for evaluating therapeutic efficacy. To address these challenges, Labcorp developed a Specialized Lipids Panel LDT on the Roche Cobas 8000 c702 that integrates precipitation-based HDL-C with ultracentrifugation-derived LDL-C, providing a higher accuracy alternative to conventional lipid measurements. Methods This Laboratory Developed Test (LDT) panel measures HDL -C isolated from neat serum using dextran sulfate precipitation and quantified with the Roche Total cholesterol assay. Total cholesterol in the ultracentrifugation bottom fraction was also quantified using the Roche assay. LDL-C was calculated by subtracting HDL-C from the cholesterol concentration of the bottom fraction. Method validation followed Labcorp SOPs and CLSI guidelines, assessing linearity, precision, accuracy, sensitivity, specificity, dilution linearity, and stability. EP Evaluator® was used for statistical analysis. Results Analytical measuring ranges were 0.260–5.170 mmol/L (HDL-C) and 0.260–20.690 mmol/L (LDL-C). Intra assay CVs were =4.1% (HDL-C) and =5.2% (LDL-C); inter assay CVs =5.4% and =6.8%. Accuracy was demonstrated with acceptable CDC reference and spike and recovery results. The LLOQ for both analytes was 0.260 mmol/L. No clinically significant interference was observed from hemoglobin (=862 mg/dL HDL-C; =711 mg/dL LDL-C), triglycerides (=0.3 mg/dL; =46 mg/dL), conjugated bilirubin (=20 mg/dL; =7 mg/dL), or unconjugated bilirubin (=42 mg/dL; =10 mg/dL). Manual dilution to 1:16 extended ULOQs to 82.720 mmol/L (HDL-C) and 331.040 mmol/L (LDL-C). Stability was confirmed for 14 days refrigerated and at -70?°C. Conclusion The Specialized Lipids Panel LDT demonstrated robust analytical performance and meets Labcorp’s acceptance criteria for clinical use. By leveraging precipitation-based HDL-C and ultracentrifugation-derived LDL-C, this LDT provides a more accurate alternative to estimation formulas and direct homogenous assays, particularly in complex lipid profiles.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Analytical validation of a direct lipoprotein(a)-cholesterol assayJournal of Lipid Research · 2026
- B-300 Validation of the Lp(a) Ultra Assay on Beckman Coulter AU680: Overcoming Isoform Heterogeneity Challenges in Lipoprotein(a) MeasurementClinical Chemistry · 2026
- B-015 Precision Compatibility - Clinical Comparative Study of Lipid Panel Reagents on Six Mainstream InstrumentsClinical Chemistry · 2026
- A-293 Sustainability Through the Implementation of Evidence-Based Equations: A Pilot Study using the Friedewald and NIH-Sampson EquationsClinical Chemistry · 2026
- 115 Apolipoprotein B Reveals Systematic Underestimation of Atherogenic Lipoprotein Burden by LDL Cholesterol Across Estimation MethodsAmerican Journal of Clinical Pathology · 2026
- Analytical Agreement and Diagnostic Performance of a Commercial Point-of-Care Lipid Testing System for Lipid Profile and Atherogenic Ratios.Diagnostics (Basel, Switzerland) · 2026