Motion-corrected Noise2Noise denoising for structural analysis of cells and tissues with (cryo-)FIB/SEM.
Vicente González-Ruiz, José-Jesús Fernández
Informatics Dept., CeinsaUAL, CINN-CSIC Associated Unit, Almería University, 04120 Almería, Spain. · Spanish National Research Council (CINN-CSIC). Asturias Health Research Institute (ISPA), 33011 Oviedo, Spain.
Key points
From the paper's conclusion- A method to enable Noise2Noise denoising in (cryo-)FIB/SEM is introduced. The input volume is split into even and odd slices followed by the application of motion correction methods to estimate and compensate for the structural differences between the two subvolumes. The resulting motion-corrected subvolumes are then used to train the Noise2Noise model, which is ultimately applied to denoise the original volume. Representative (cryo-)FIB/SEM volumes have been used to validate the method and to demonstrate the critical importance of the motion correction stage for volumes with a slice thickness greater than 10 nm.
Abstract
MOTIVATION: (Cryo-)FIB/SEM enables three-dimensional (3D) ultrastructural analysis of cells and tissues at nanoscale resolution. However, its characteristically low signal-to-noise ratio severely hinders interpretation of the volume data. Noise2Noise has emerged as a state-of-the-art denoising paradigm with outstanding performance in 3D electron microscopy -particularly cryo-ET- but its direct application to (cryo-)FIB/SEM remains unfeasible due to the inherent acquisition workflows. RESULTS: A method to enable Noise2Noise denoising in (cryo-)FIB/SEM is introduced. The input volume is split into even and odd slices followed by the application of motion correction methods to estimate and compensate for the structural differences between the two subvolumes. The resulting motion-corrected subvolumes are then used to train the Noise2Noise model, which is ultimately applied to denoise the original volume. Representative (cryo-)FIB/SEM volumes have been used to validate the method and to demonstrate the critical importance of the motion correction stage for volumes with a slice thickness greater than 10 nm. AVAILABILITY AND IMPLEMENTATION: Code is available at https://github.com/microscopy-processing/N2N-REO and https://doi.org/10.5281/zenodo.22303478. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Artifact-guided restoration improves visualization of cellular ultrastructure in cryo-FIB-SEM volumesbioRxiv · 2026
- CryoET-DDM: restoring high-fidelity signals in cryo-electron tomography via a data-driven diffusion model.Bioinformatics (Oxford, England) · 2026
- Enhancing microstructural fidelity in near-field high-energy diffraction microscopy reconstruction with Noise2Void denoising.Journal of applied crystallography · 2026
- AreTomoLive: automated reconstruction of comprehensively corrected and denoised cryo-electron tomograms in real time and at high throughputNature Methods · 2026
- From Unsupervised to Zero-Shot: 3D Domain Adaptation for Cryo-Electron Tomography Segmentation.International journal of computer vision · 2026
- On-lamella dual-axis cryo-electron tomography and modelling of lamella stabilityBMC Methods · 2026