BMC MethodsOpen accessLamella

On-lamella dual-axis cryo-electron tomography and modelling of lamella stability

Moritz Wachsmuth-Melm, Cornelis Mense, Santiago Gomez Melo, Liv Zimmermann, Ulrich S. Schwarz, Petr Chlanda

Heidelberg University

Key points

From the paper's conclusion
  • Together, these methods increase cryo-ET data quality and throughput and offer valuable training datasets for the further development of deep learning–based restoration approaches.

Abstract

Abstract Background Cryogenic electron tomography (cryo-ET) of cryogenic focused ion beam (cryo-FIB)–milled lamellae enables visualization of three-dimensional cellular architecture in near-native conditions at nanometer-scale resolution. However, cryo-FIB milling is typically performed using rectangular patterns that limit the accessible tilt range, precluding dual-axis tomography. In addition, cryo-lamellae must remain mechanically connected to the cell body and are prone to fracture during preparation and transfer to the cryo-transmission electron microscope (cryo-TEM), reducing experimental throughput. Methods We developed a cryo-FIB trapezoid milling strategy that permits dual-axis cryo-ET by enabling grid loading with the tilt axis oriented perpendicular to the milling direction. Dual-axis and single-axis cryo-ET datasets were acquired and compared, including single-axis tomograms processed with deep learning–based missing wedge restoration. To address lamella stability, we performed finite element–based mechanical simulations to calculate the build-up of von Mises stresses within different lamella geometries and milling designs. Results Dual-axis cryo-ET provided additional three-dimensional information compared to conventional single-axis tomography and to single-axis tomograms after deep learning–based missing wedge restoration. This resulted in improved tomogram interpretability and segmentation quality. Furthermore, the mechanical simulations identified stress accumulation and fracture-prone regions within cryo-lamellae, allowing the rational design of milling patterns with enhanced mechanical stability. Conclusions The trapezoid cryo-FIB milling strategy enables routine dual-axis cryo-ET of cellular lamellae, improving 3D information content and segmentation quality. In addition, the finite element–based mechanical framework provides a predictive tool for optimizing lamella design and stability. Together, these methods increase cryo-ET data quality and throughput and offer valuable training datasets for the further development of deep learning–based restoration approaches.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

On-lamella dual-axis cryo-electron tomography and modelling of lamella stability — Science Skim