Extra-Large Blood Pressure Cuff Need and Cost Burden in United States Adults with Hypertension.
Sumit Sahoo, Tammy Brady, Benjamin Grobman, Stephen P Juraschek, Jennifer L Cluett
Northeastern University, Boston, MA. · Children's National Hospital, Washington, DC.
Key points
From the paper's conclusion- More than 7 million US adults with hypertension require an extra-large BP cuff; the substantially higher cost of extra-large cuff-compatible devices represents an important and underrecognized barrier to accurate home BP monitoring.
Abstract
BACKGROUND: Accurate home blood pressure (BP) monitoring depends on appropriate cuff sizing, but the prevalence and cost implications of extra-large cuff need among US adults with hypertension are unknown. METHODS: Using pooled data from 2017-2023 National Health and Nutrition Examination Survey (NHANES) with survey weighting, we estimated the prevalence of having a mid-arm circumference >43cm among US adults with hypertension, overall and by race/ethnicity. We also categorized home BP monitors listed on the US Validated Device Listing as standard (accommodating arm circumferences from 22-43cm) or extra-large cuff compatible (accommodating arm circumferences >43cm). RESULTS: Approximately 6.6% of US adults with hypertension (∼ 7.2 million individuals) had an arm circumference >43cm. Prevalence was highest among Non-Hispanic (NH) Black adults (11.4%) followed by Other Race/Multiracial (8.2%), NH White (6.2%), Hispanic (5.3%) and NH Asian adults (0.9%). Of the 51 validated devices, only 22 (43.1%) accommodated arm circumferences >43cm. The mean total cost of an extra-large cuff compatible system was 32.7% higher ($99.06 versus $74.70 for standard devices). CONCLUSIONS: More than 7 million US adults with hypertension require an extra-large BP cuff; the substantially higher cost of extra-large cuff-compatible devices represents an important and underrecognized barrier to accurate home BP monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Exaggerated blood pressure response to exercise: bridging the gap between evidence and guidelines.Clinical hypertension · 2026
- Disparities in Blood Pressure Measurement.Current hypertension reports · 2026
- Office blood pressure measurement versus ambulatory blood pressure monitoring for detecting undiagnosed hypertension in an apparently healthy Mexican adult cohort: complementary central hemodynamic and arterial stiffness assessment.Frontiers in cardiovascular medicine · 2026
- Toward patient-centered blood pressure monitoring: first evaluation of a low-pressure and rapid oscillometric method for reducing cuff-related measurement burden.Hypertension research : official journal of the Japanese Society of Hypertension · 2026
- Toward patient-centered blood pressure monitoring: validation of a novel low-pressure and rapid oscillometric method according to the ISO 81060-2:2018/Amd1:2020/Amd2:2024 standard.Hypertension research : official journal of the Japanese Society of Hypertension · 2026
- Calf blood pressure measurement for detecting elevated arm blood pressure in hemodialysis patients.Current medical research and opinion · 2026