50 Impact and Potential Clinical Consequences of Intravenous Fluid Contamination on Coagulation Testing Results
Carly Maucione, Christopher Farnsworth, Nick Spies, Timothy Parker, Derek Harford, Nathan McLamb, Ron Jackups, Mark Zaydman
Key points
From the paper's conclusion- In future work, we aim to determine the impact of IV fluid contamination on downstream medical decision making, including the administration of cryoprecipitate.
Abstract
Intravenous (IV) fluid contamination of laboratory specimens occurs when a specimen is drawn from or proximal to a fluid-infusing line, which can lead to unreliable results that can misguide management, and thus harm patients. Machine learning (ML) has been used to detect IV fluid contamination in BMPs at a rate of 2.1%. Recently, the prevalence of IV fluid contamination of CBCs was found to be as high as 3.7-5.2%, which may have inappropriately motivated up to 8% of the included inpatient single-unit red blood cell transfusions at a single academic hospital. Given these findings, we sought to determine the impact and potential consequences of IV-fluid contamination on coagulation studies, which remains largely undefined. Methods All PT, aPTT, and fibrinogen results with a concurrent BMP and CBC under the same accession were extracted from the EMR over a 1-year period. Coagulation studies with significant contamination were defined as those with a concurrent contaminated specimen, identified with previously published ML pipelines for detecting BMP contamination. Mixture ratios on contaminated results were estimated by previously published regression models. Wet bench mixing studies were used to determine the effects of contamination at increasing mixture ratios on coagulation study results. Results Of the 80,513 coagulation studies from 35,231 unique patients included in the study period, a prediction was able to be made on 60,955 (76%). 3.8% of the coagulation studies were predicted to be contaminated at a mixture ratio of 10% or greater, the threshold identified as significant for BMP contamination in prior studies. By visual inspection, PT and aPTT were insensitive to contamination until an estimated mixture ratio of approximately 30%, above which both studies exhibited prolongation in clotting times. In contrast, fibrinogen concentration measurements decreased in roughly linear proportion with increasing estimated mixture ratio. Of note, only 0.03% of predicted contaminated samples had an estimated mixture ratio of > 30%. In vitro mixing studies correlated these findings, showing 1) PT and aPTT appear insensitive to mild contamination but exhibit prolongation for >30% contamination, and 2) fibrinogen exhibits a linear dilutional pattern at all tested mixture ratios. Conclusion These findings suggest that IV fluid contamination is unlikely to affect most PT or aPTT studies, given the rarity of severe contamination >30%. However, IV fluid contamination may be an underrecognized preanalytical error affecting fibrinogen testing, as it appears to be sensitive to contamination at all mixture ratios. In future work, we aim to determine the impact of IV fluid contamination on downstream medical decision making, including the administration of cryoprecipitate.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- FluidFlagger: An Open-Source Machine Learning Application for Automated Detection of Intravenous Fluid Contamination in Laboratory Results.The journal of applied laboratory medicine · 2026
- Simulation-Based Machine Learning as a Benchmarking Tool for the Retrospective Identification of IV Fluid Contamination in Basic Metabolic Panels.The journal of applied laboratory medicine · 2026
- 182 Leveraging an Automated Delta-Check Rule to Flag Critical Preanalytical Errors in Coagulation Testing: A 14-Month Lab Practice InterventionAmerican Journal of Clinical Pathology · 2026
- Building blocks for the prevention of blood culture contamination: A quality improvement intervention in emergency departmentIndian Journal of Medical Microbiology · 2026
- Risk of blood culture contamination during central venous catheter insertion in critically ill adults: a self-controlled study.Journal of critical care · 2026
- A-118 A simple and effective method to reduce blood culture contamination rate (BCCR)Clinical Chemistry · 2026