Clinical Chemistry

A-118 A simple and effective method to reduce blood culture contamination rate (BCCR)

Narayan Torke, Dani Bodecker, Allison Boehler, Breanna Caraway, Marella Lucas

Computational

Key points

From the paper's conclusion
  • By implementing a simple, inexpensive blood diversion technique as described above, our laboratory has significantly reduced BCCR to positively impact patient safety and care.

Abstract

Background Blood culture (BC) contamination occurs when microorganisms that are not actually causing a bloodstream infection are introduced into a blood culture sample either during phlebotomy, or through skin flora. Blood contamination can lead to inaccurate diagnoses, unnecessary antibiotic treatment, and prolonged hospital stays. Minimizing blood culture contamination rates (BCCR) is an important quality improvement tool. Current benchmark for BCCR in the U.S. is <3%, although many facilities have been able to drive this to below 2% through various strategies. Employing a simple, initial ‘discard tube’ method, our laboratory has shown BCCR can be reduced to significantly lower than 1%. Methods The blood collection site was prepared using established phlebotomy procedures. Upon insertion of the needle into the collection site, the initial portion of the blood drawn was diverted to a ‘discard’ tube (approximately 2.0 mL) and the same needle was subsequently used to aseptically inject blood culture specimens into BD BACTEC culture bottles. These bottles were then placed into BD BACTEC™ FX instrument for incubation and testing. Each bottle contained a sensor which detected increases in CO2 levels produced by the growth of microorganisms. Bottles were automatically reviewed at defined intervals for chemical changes in the sensor which indicated bacterial growth (Positive BC). Positive bottles were removed from BACTEC™ FX, sub-cultured to plates for bacterial/fungal ID and sensitivity, gram stained and tested by PCR for the most common blood culture pathogens. Results A total of 1,511 blood cultures from Emergency Department and hospitalized patients collected over a period of 3 months were included in the study. Of these, 112 cultures were positive for a positivity rate of 7.4%. Three specimens were considered contaminated for a BCCR of 0.2%. This result compared to the pre-study baseline of 2.3% BCCR, indicating an overall performance improvement of 91%. The contamination rate was primarily in the specimens from the Emergency Department, given the serious challenges posed for infection control and prevention. A contaminated BC sample gave a positive reading but did not indicate a clinically relevant result. BC contaminations were determined based on such factors as type of organism recovered, occurrence of the same organism in multiple cultures and patient history, etc. Comparison of the results with the list of organisms on file and generally considered non-pathogenic was a part of the evaluation process. Conclusion Maintaining a low BCCR substantially improves accurate diagnosis of infections. False positive results due to contamination and insufficient blood culture volume can result in such serious consequences as misdiagnosis, repeat diagnostic testing, delayed accurate diagnosis, unnecessary antibiotic exposure, prolonged length of hospitalization and related unnecessary added costs. By implementing a simple, inexpensive blood diversion technique as described above, our laboratory has significantly reduced BCCR to positively impact patient safety and care. Commercial devices available for lowering BCCR are effective, but expensive. The method described in this report can accomplish similar outcomes at a fraction of the cost.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers