251 Impact of BD MAP Microtube® Implementation on Hematology Turnaround Time
Bailee Thompson, Allison Hermane, Claudio Mosse, Joe Wiencek
Key points
From the paper's conclusion- We adopted it to automate small-volume processing and evaluated its 12-month impact.
Abstract
Introduction/Objective Standard microtainers® for small-volume hematology specimens cannot run on the automated line and require manual loading, repeats, and slide prep, adding turnaround time (TAT) and variability. The BD MAP Microtube® holds the same volume but has a false bottom compatible with laboratory automation. We adopted it to automate small-volume processing and evaluated its 12-month impact. Methods/Case Report We reviewed 89,050 hematology specimens at Monroe Carell Jr. Children’s Hospital at Vanderbilt (MCJCH), where short draws (or small volume) are most concentrated, over 20 months (September 2024 to April 2026). Adoption grew from 0% to 90% over the study period. Differences were tested with Mann-Whitney U and Brown-Forsythe. Monthly TAT was regressed on adoption. Statistical Process Control (SPC) and P-charts tracked trends and 60/120-minute compliance. Results Mean TAT dropped from 30.9 to 26.7 min. Each percentage point increase in adoption reduced TAT by 0.047 minutes (R² = 0.51, p Conclusion The implementation of the BD MAP Microtube® significantly decreased mean TAT and reduced TAT variability at Vanderbilt Medical Laboratories.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- B-043 Comparison of Turnaround Time of Beckman Coulter Power Processor and DxA 5000 Automated SystemsClinical Chemistry · 2026
- How do pre-barcoded tubes improve preanalytical workflow? A survey study.Clinical chemistry and laboratory medicine · 2026
- Performance Assessment of Centrifugation-Based Hematocrit Testing in Primary Care Units: Evidence from Seventy-Two Proficiency Testing Datasets over Eight Years.Diagnostics (Basel, Switzerland) · 2026
- Sample volume management: the role of the clinical laboratory in minimizing diagnostic blood loss.Clinical chemistry and laboratory medicine · 2026
- Performance evaluation of the pneumatic tube system for urine, haematology, coagulation, biochemical and immunological testsTurkish Journal of Biochemistry · 2026
- Implementation of a Hospital-Wide Blood-Sparing Sampling Protocol and Changes in Blood Conservation, Transfusion Use, Costs, and Environmental Sustainability: A Pre–Post Quality Improvement StudyIJQHC Communications · 2026