132 Improving Phenytoin Therapeutic Drug Monitoring Accuracy Using Six Sigma Metrics
Joshua Morse, Liyun Cao
Key points
From the paper's conclusion- Conclusion Six Sigma analysis demonstrated that the CMIA assay on the Abbott Architect i2000 provides substantively more reliable analytical performance for phenytoin monitoring across therapeutic concentrations.
Abstract
Introduction/Objective Accurate therapeutic drug monitoring (TDM) of phenytoin is essential due to its narrow therapeutic index and substantial pharmacokinetic variability. This study evaluated the analytical performance of two phenytoin assays using Six Sigma methodology to identify accuracyrelated gaps and guide method selection. Methods/Case Report Phenytoin concentrations were measured using the SYVA EMIT 2000 assay on the Beckman AU5800 and a CMIA assay on the Abbott Architect i2000. Six Sigma metrics were calculated using EP Evaluator EE12. Precision was assessed using routine QC materials, and bias was evaluated using CAP Survey materials and linearity study materials. Results The EMIT 2000 assay on the Beckman AU5800 demonstrated substantial positive bias (+2.47 µg/mL at 10 µg/mL, +2.13 µg/mL at 20 µg/mL) and high imprecision (CV 9–10%), resulting in sigma values below 1σ at both decision points—an indication of unacceptable analytical performance. In contrast, the CMIA assay on the Abbott Architect i2000 showed minimal bias (+0.39 µg/mL at 10 µg/mL, +0.63 µg/mL at 20 µg/mL) and low imprecision (CV 2–3%), yielding sigma values of 5.1σ at 10 µg/mL and 4.7σ at 20 µg/mL. Conclusion Six Sigma analysis demonstrated that the CMIA assay on the Abbott Architect i2000 provides substantively more reliable analytical performance for phenytoin monitoring across therapeutic concentrations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Longitudinal Sigma-Metric Profiling of Two Clinical Chemistry Platforms Using Peer-Group Internal Quality Control.Diagnostics (Basel, Switzerland) · 2026
- B-387 Analytical Precision and on-board stability Evaluation of the EMIT Methotrexate and Amikacin and EMIT 2000 Vancomycin and Digoxin Assays on the Atellica DT 250 AnalyzerClinical Chemistry · 2026
- B-266 A multisite review across the USA of major competitive biochemistry platforms reveals significant differences in analytical performanceClinical Chemistry · 2026
- Evaluation of Pre-Analytical Performance Using IFCC Quality Indicators, Six Sigma Metrics and Root Cause Analysis in a Biochemistry Laboratory-A Retrospective Study.Diagnostics (Basel, Switzerland) · 2026
- Sigma metric and Quality Goal Index assessment of hemoglobin A1c analytical performance in an ambulatory accredited laboratory.Laboratory medicine · 2026
- Quality Indicator-Driven Six Sigma Scale Assessment of Extra-Analytical Phases in Clinical Chemistry Laboratory-Insights from a Tertiary Care Hospital.Annals of clinical biochemistry · 2026