Measurement and Analysis of Currents for Diagnosing Insulation Degradation in Three-Phase AC Machines
Paulo Lamim, Fabiano Batista, João Baccarini, Lane M. Rabelo Baccarini
Key points
From the paper's conclusion- During the same test, the three-phase values are compared with one another.
For diagnostic decisions in subsequent measurements, these results are evaluated against a
reference threshold that was previously established under healthy machine conditions.
Experimental validation on a three-phase induction motor confirms that the proposed
method effectively identifies and tracks the in
Abstract
Due to the widespread use of three-phase induction machines and the severity of short-circuit faults in stator windings, considerable research effort has been devoted to developing early diagnostic tools for this type of fault. The complexity stems from the inherent coupling of machine circuits, which can cause distinct fault conditions to exhibit similar signatures, thereby increasing the likelihood of misdiagnosis, including false-positive and false-negative detections. This study presents a novel method, named the Stator Winding Degradation Indicator (SWDI), for monitoring three-phase windings and diagnosing incipient insulation degradation. The method consists of individually exciting each stator phase with the machine switched off, disconnected from the power supply, and out of operation, and evaluating the fundamental component of the current. The corresponding quantities from the three phases are then compared under the same test conditions, allowing detection of small asymmetries associated with insulation degradation. During the same test, the three-phase values are compared with one another. For diagnostic decisions in subsequent measurements, these results are evaluated against a reference threshold that was previously established under healthy machine conditions. Experimental validation on a three-phase induction motor confirms that the proposed method effectively identifies and tracks the insulation degradation levels. This approach is straightforward and practical, enabling the assessment of insulation degradation under low-voltage excitation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Interpretable Fault Diagnosis of Shearer Power-Core Cables from Sensor-Accessible Terminal Electrical Responses.Sensors (Basel, Switzerland) · 2026
- Physics-Guided Machine Learning for Joint Fault Diagnosis in Inverter-Fed Induction Motor DrivesEnergies · 2026
- Knowledge Distillation From Electromagnetic Simulation for Asynchronous Motor Fault Diagnosis With Small Labeled SamplesIEEE Transactions on Transportation Electrification · 2026
- Domain Adaptive Induction Motor Diagnosis Using Residual Maximum Kernel Discrepancy Adaptation NetworkMachines · 2026
- An integrated change-point detection framework for wind turbine monitoring and fault diagnosis using SCADA dataEnergy · 2026
- An Insulation Condition Assessment Method for Stator Windings of Pumped-Storage Generators Based on Sparsity-Promoting Dynamic Mode Decomposition of Depolarization CurrentEnergies · 2026