An Insulation Condition Assessment Method for Stator Windings of Pumped-Storage Generators Based on Sparsity-Promoting Dynamic Mode Decomposition of Depolarization Current
Yi Lv, Guangya Zhu, Jiachen Liu, Yunchang Liu, Shiyu Ma, Lijun Kong, Shiquan Cao
Key points
From the paper's conclusion- The results show that the proposed method can automatically determine the branch number of the extended Debye model and effectively identify the branch parameters related to the relaxation processes of the main insulation, thereby providing dielectric-response parameter support for offline insulation condition assessment of stator windings in pumped-storage generator-motors.
Abstract
For pumped-storage generator-motors, stator-winding main insulation is subjected to repeated electrical, thermal, and mechanical stresses during frequent operating-mode transitions. To precisely detect the main insulation condition of the stator windings in pumped-storage motors and identify key parameters related to the insulation medium’s conductivity and relaxation processes, this paper proposes a method based on sparse-promoted dynamic mode decomposition of depolarization current. First, the time series of depolarization current is decomposed using dynamic mode decomposition. Then, the optimal amplitude coefficients for different modes are calculated using the alternating direction method of multipliers. This process separates the dominant mode, which represents the relaxation characteristics of the main insulation, from spurious modes representing noise interference. The dominant mode is used to calculate the parameters of the extended Debye model, enabling precise identification of relaxation characteristics. Finally, the proposed method is verified using both preset-model simulations and PDC experiments on stator bars under different thermal aging conditions. The results show that the proposed method can automatically determine the branch number of the extended Debye model and effectively identify the branch parameters related to the relaxation processes of the main insulation, thereby providing dielectric-response parameter support for offline insulation condition assessment of stator windings in pumped-storage generator-motors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robust Estimation Method for Power Angle and Stator Voltage of Pumped-Storage Units Based on Res–Autoformer and Unscented Particle FilterElectronics · 2026
- Subsynchronous Oscillation Parameters Identification Method for DFIG Based on NGO‐Optimized MVMD and Improved TLS‐ESPRITInternational Transactions on Electrical Energy Systems · 2026
- Compositional Data-Driven Small-Signal Stability Assessment of Power Systems via Output Differential PassivityarXiv · 2026
- Synchrophasor-Based Parameter Identification of Sub/Super-Synchronous Oscillations Using Adaptive Empirical Fourier DecompositionIEEE Transactions on Power Delivery · 2025
- Measurement-Driven Koopman Dynamic Equivalencing with Modal Preservation for Small-Signal Stability Assessment of Power SystemsSensors · 2026
- Adaptive Grid-Mode-Aware Hybrid Energy Storage Control for AI Data Center Oscillation MitigationarXiv · 2026