  • The EECM is used to compute AC resistance across the full frequency range, and the computed values are compared against directly measured values for standards of 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, and 100 kΩ, showing good agreement.

Abstract

High-frequency characterization of AC resistance standards is critical in impedance metrology to bridge the gap between the audio-frequency and radio-frequency, also known as LF-RF gap. In the present work, four-terminal-pair (4TP) AC resistance standards are characterized from 10 kHz to 1 MHz to address the LF-RF traceability gap in impedance metrology. An electrical equivalent circuit model (EECM) is employed to describe the frequency dependence of resistance, with the resistance value at 1 kHz as the reference and the measured parasitic components as model inputs. The EECM is used to compute AC resistance across the full frequency range, and the computed values are compared against directly measured values for standards of 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, and 100 kΩ, showing good agreement. Measurement uncertainty is estimated using the uncertainty propagation method in accordance with the Guide to the expression of uncertainty in measurement (GUM). The proposed technique is applied to calibrate an LCR meter for AC resistance from 10 kHz to 1 MHz, demonstrating a practical, traceable route for extending AC resistance calibration capability into the MHz range.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers