Cyber-Resilient Load Frequency Control of Multi-Area Renewable Power Systems Using HNN-Based Sliding Mode Control with V2G
BHUPESH KUMAR NAMDETI, Naga Siva Rama Murthy V, Madhu Sagar babu G, Venugopal Dugyala, Swetha Kannepally
Key points
From the paper's conclusion- This study presents a novel Load Frequency Control (LFC) architecture for multi-area power systems that incorporates photovoltaic (PV) generation, energy storage systems (ESS), and electric vehicle vehicle-to-grid (EV-V2G) capabilities.
Abstract
This study presents a novel Load Frequency Control (LFC) architecture for multi-area power systems that incorporates photovoltaic (PV) generation, energy storage systems (ESS), and electric vehicle vehicle-to-grid (EV-V2G) capabilities. The central contribution involves formulating a Hopfield Neural Network-integrated Sliding Mode Controller (HNN-SMC) a configuration not previously explored within the context of multi-area LFC. The Hopfield Neural Network (HNN) serves as an embedded, real-time optimization engine within the sliding mode control law, deriving adaptive control gains by continuously minimizing a quadratic Lyapunov energy function with no dependency on pre-trained models. A redefined global fast terminal sliding surface incorporating a nonlinear, timevarying decay mechanism provides finite-time convergence guarantees along with universal robustness. The EV-V2G component is treated as a stochastically available bidirectional energy resource, thereby expanding the frequency regulation potential beyond what PV-ESS configurations alone can offer. Furthermore, an HNN-based anomaly detection module is embedded within the control architecture, conferring resilience against cyber-threats -specifically communication delays, packet loss events, false data injection (FDI) attacks, and replay attacks. Closed-loop stability is rigorously substantiated using an augmented Lyapunov function. Validation through simulations on a two-area LFC benchmark and the IEEE 39-bus test network reveals that HNN-SMC achieves reductions of 81.2% in steady-state frequency error, 70.4% in settling time, and 43.7% in peak frequency deviation relative to PID, SMC, and GFTSMC reference controllers. When subjected to the most severe combined cyber-attack scenario involving simultaneous delays, packet loss, and FDI, the proposed cyber-secure HNN-SMC keeps frequency deviation within 0.245 Hz, outperforming unprotected GFTSMC and AGFTSMC baselines which breach 0.350 Hz. The proposed scheme operates without offline training and delivers a computationally lean, robust, and cyber-secure solution for frequency governance in high-penetration renewable energy systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adjustable Predefined-Time Sliding-Mode Frequency Control of Microgrids with Hybrid Energy Storage Systems and CyberattacksElectronics · 2026
- Hybrid Microgrid Power Management via a CNN–LSTM Centralized Controller Tuned with Imperialist Competitive AlgorithmMathematics · 2025
- Data-driven integrated method for frequency security assessment and control in power systemsInternational Journal of Electrical Power & Energy Systems · 2026
- A Novel Utilization Factor‐Based Adaptive Coordination Strategy for Electric Vehicle‐to‐Grid and Energy Storage in Peak Load ManagementEnergy Storage · 2026
- A Two-Layer Distributed Event-Triggered Active Frequency and Voltage Control Framework for HVDC-Connected Wind FarmsElectronics · 2026
- Energy storage-enabled fractional-order virtual synchronous generator for DC-link voltage regulation in DC microgrid under load and renewable disturbancesScientific Reports · 2026