Plasma Science and Technology

First measurement of heat flux on the W/Cu monoblock structure divertor with surface eroding thermocouple (SETC) in EAST

Yifeng Wang, Ran Chen, Lei Cao, Jun Ren, Ning Yan, Kedong Li, Bin Zhang, Guosheng Xu,

Key points

From the paper's conclusion
  • The surface eroding thermocouple (SETC) diagnostic has recently been deployed in the Experimental Advanced Superconducting Tokamak (EAST), designed to measure the surface temperature and heat flux on the W/Cu monoblock divertor target plates.

Abstract

The surface eroding thermocouple (SETC) diagnostic has recently been deployed in the Experimental Advanced Superconducting Tokamak (EAST), designed to measure the surface temperature and heat flux on the W/Cu monoblock divertor target plates. As of 2024, a total of 15 SETC probes has been installed in the lower divertor, with 8 in the outer vertical target plate and 7 in the inner vertical target plate. These Type-C thermocouple probes are capable of directly contacting the divertor plasma at surface temperature exceeding 2000 °C. Signal calibration has been performed to eliminate inductive noise and obtain the actual temperature values. The heat flux is then derived from the temperature measurement using a three-dimensional heat transfer model built with the COMSOL Multiphysics code. The heat flux obtained from the SETC diagnostic exhibits temporal trends generally consistent with that from the infrared (IR) diagnostic in EAST. Benefiting from its fast response capability, this diagnostic can resolve transient events on the 10-ms time scale in EAST, such as the L–H transition. The SETC diagnostic has also been successfully applied in long-pulse H-mode operations in EAST, preliminarily demonstrating its reliability for long-pulse scenarios.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers