Three-dimensional assessment of toroidal heat-load distribution on divertor targets in EAST
Wenxue Fu, Dahuan Zhu, Binfu Gao, Rong Yan, Chuannan Xuan, Yang Wang, Yang Lei, Bin Zhang,
Key points
From the paper's conclusion- These results show that magnetic ripple, assembly tolerance and toroidal geometric continuity should be considered together in divertor thermal design.
Abstract
Although actively cooled W/Cu monoblock targets are designed for high steady-state heat exhaust, local overheating and damage have been observed on these targets in EAST. These observations indicate that, beyond the nominal heat-removal capability, the practical thermal margin can be affected by engineering alignment, target geometry and plasma operating conditions, which modify the local surface-normal heat flux through magnetic incidence and magnetic shadowing. In this work, the toroidal heat-load distribution on EAST divertor targets is analysed by combining infrared thermography, finite-element heat-flux inversion and three-dimensional field-line tracing using PFCFlux. The analysis focuses on the effects of toroidal-field ripple, ripple-coupled cassette misalignment and divertor target geometry. The 16-fold toroidal-field ripple produces a 2π/16 modulation of the peak heat flux on the present upper outer target, with a peak fluctuation amplitude of approximately 17.75%. Under a peak heat-flux constraint of Qsafe = 10 MW m-2, the allowable average heat flux decreases from 4.28 MW m-2 without ripple to 3.94 MW m-2 with ripple. When ripple and relative cassette misalignment are considered together, it is further reduced to 3.11, 2.79 and 2.27 MW m-2 for Delta = 0.6, 1.0 and 3.0 mm, respectively. Comparison with the lower divertor shows that improved toroidal continuity reduces ripple-only peak amplification. Using the lower outer horizontal target as a reference, the new upper horizontal target reaches an allowable average heat flux of 4.70 MW m-2 under ripple and Δ = 1 mm misalignment. These results show that magnetic ripple, assembly tolerance and toroidal geometric continuity should be considered together in divertor thermal design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Compensation of 1/1 and 2/2 error field in Wendelstein 7-X via divertor heat load symmetrizationNuclear Fusion · 2026
- First measurement of heat flux on the W/Cu monoblock structure divertor with surface eroding thermocouple (SETC) in EASTPlasma Science and Technology · 2026
- Improving heat flux calculations for the non-axisymmetric loads on plasma facing components in Wendelstein 7-XReview of Scientific Instruments · 2026
- First Wall Design of a Tokamak Pilot Plant Using a Monte Carlo Model for 3-D Heat Flux DepositionIEEE Transactions on Plasma Science · 2026
- Role of Device Size on Island Divertor Performance of W7-X-like ConfigurationsarXiv · 2026
- Heat Load Mitigation Studies in the W7 ‐X Stellarator ExperimentContributions to Plasma Physics · 2026