Biomedical physics & engineering express

Arbitrary-Scale Super-Resolution for Non-Contrast Coronary MRA via Wavelet-Laplacian Enhanced Implicit Network.

Yue Yin, Run Zhang, Yue Jiang, Da Cao, Funan Xiao, Chuanbing Wang, XiuHan Li

Department of Medical Engineering, Southeast University Zhongda Hospital, No. 211, Jianmin Road, Liuhe District, Nanjing, Nanjing, Jiangsu, 210009, China. · Engineering Research Center of Intelligent Theranostics Technology and Instruments, Nanjing Medical University, No. 101, Longmian Avenue, Jiangning District, Nanjing, Nanjing, 210029, China.

Key points

From the paper's conclusion
  • We propose an arbitrary-scale super-resolution framework that integrates a physiology-aware degradation model with a Wavelet-Laplacian Enhanced Implicit Network (WLEI-Net).

Abstract

Non-contrast coronary magnetic resonance angiography (NC-CMRA) provides a radiation-free and contrast-free approach for coronary assessment, but its diagnostic value is limited by insufficient spatial resolution. We propose an arbitrary-scale super-resolution framework that integrates a physiology-aware degradation model with a Wavelet-Laplacian Enhanced Implicit Network (WLEI-Net). The degradation model sequentially represents heart-rate-variability-driven asymmetric cardiac motion, Ornstein-Uhlenbeck respiratory translation, cardiopulmonary coupling, band-limited k-space noise, and Rician magnitude formation, and is designed to better represent the coupled physiological and k-space effects of clinical acquisitions. WLEI-Net combines SwinIR feature extraction, directional wavelet subband enhancement with channel attention, noise-adaptive Laplacian edge compensation, and a hybrid Charbonnier-wavelet-Sobel loss. Using 380 NC-CMRA images from 12 patients with a fixed patient-level split, the arbitrary-scale models were trained at 4.0× and evaluated at 2.0×, 2.5×, 3.0×, 3.5×, and 4.0×, with the four other evaluated scales unseen during training. WLEI-Net achieved the best mean performance for all six metrics at all five scales, and all comparisons against the four baselines remained significant after Benjamini-Hochberg false-discovery-rate correction (BH-adjusted p ≤ 0.012). In a blinded two-reader evaluation of 57 test images at 2.5× and 4.0×, WLEI-Net achieved the highest mean score for artifact/noise suppression, vascular edge integrity, and small-branch visibility, with ICC(2,2)=0.817-0.901. These results support internal reconstruction and reader-perceived image-quality benefits.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers