PABCNet: A super-resolution network for non-contrast coronary MRA with inter-slice fusion and Bayesian confidence quantification.
Fangyi Xing, Ning Cao, Xiuhan Li, Tianjing Wang, Yue Jiang, Can Hu
College of Computer Science and Software Engineering, Hohai University, Nanjing, 211100, China. · College of Computer Science and Software Engineering, Hohai University, Nanjing, 211100, China. Electronic address: caoning@hhu.edu.cn.
Key points
From the paper's conclusion- Without increasing the scanning burden, the proposed method realizes high-quality super-resolution reconstruction and reliability assessment of NC-CMRA, and provides auxiliary information for the image quality assessment of non-invasive coronary artery disease.
Abstract
BACKGROUND AND OBJECTIVE: Non-contrast coronary magnetic resonance angiography (NC-CMRA) suffers from inherent low spatial resolution, whereas existing deep learning-based super-resolution methods offer no reliability assessment, which hinders their clinical adoption. METHODS: To bridge this gap, we develop a task-tailored integrated super-resolution pipeline named PABCNet, equipped with inter-slice phase alignment and calibrated Bayesian confidence quantification. PABCNet ensures data fidelity through a physics-driven low-resolution image synthesis pipeline that simulates k-space undersampling and complex noise. Crucially, to reconstruct anatomically continuous coronary structures, we configure an inter-slice feature propagation module with frequency-domain phase alignment and deformable convolution to achieve sub-pixel registration. Additionally, a Bayesian confidence quantification module employs Monte Carlo Dropout and Laplacian likelihood to jointly model epistemic and aleatoric uncertainty and generate pixel-wise confidence maps. RESULTS: Extensive experiments on a private Coronary dataset and the public CardioScans dataset demonstrate that PABCNet achieves state-of-the-art performance, with a PSNR of 35.83 dB and an SSIM of 0.9729. Notably, it achieves a vessel-region ROI-PSNR of 32.68 dB (2.18 dB higher than the second-best method). Its reliability assessment yields a low expected calibration error of 0.0234 and effectively distinguishes reliable from uncertain regions. Radiologist evaluation confirms its significant superiority in coronary clarity, cardiac structure depiction and artifact suppression over both comparative methods and original high-resolution scans. CONCLUSIONS: Without increasing the scanning burden, the proposed method realizes high-quality super-resolution reconstruction and reliability assessment of NC-CMRA, and provides auxiliary information for the image quality assessment of non-invasive coronary artery disease.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Arbitrary-Scale Super-Resolution for Non-Contrast Coronary MRA via Wavelet-Laplacian Enhanced Implicit Network.Biomedical physics & engineering express · 2026
- Biomarker-Aware Super-Resolution for 4D Flow MRI in a Synthetic Pulmonary-Artery BenchmarkbioRxiv · 2026
- CSC-Mamba: Bridging multimodal convolutional sparse coding and state space models for multi-contrast MRI super-resolutionarXiv · 2026
- Toward Clinical Translation of Deep Learning-Based Intracranial Super-Resolution 4D Flow MRI Using Multi-Cohort Transfer LearningarXiv · 2026
- Acoustic coherence-aware oriented 3D photoacoustic microscopy super-resolution with noise-suppression.Optics express · 2026
- MPISuperRes-PnP: a super-resolution zero-shot plug-and-play reconstruction algorithm for magnetic particle imaging.Physics in medicine and biology · 2026