Open-loop system identification of an AC motor-driven arterial flow generation platform: vessel-specific models and a parsimonious common ARX model.
Yilmaz Serdar, Hüseyin Yildiz, Canan Akay, Feyzi Kaysi, Herman Sedef
Technical Science Vocational School, Istanbul University-Cerrahpasa, Büyükçekmece, Avcılar, İstanbul, 34500, Turkey. · Control and Automation Technology, Istanbul University-Cerrahpasa, Mühendislik Fakültesi A BLok Kat 6 Makine Mühendisliği Bölüm, Avcılar, Istanbul, 34320, Turkey.
Key points
From the paper's conclusion- The common model provides a compact nominal representation of the tested platform.
Abstract
Accurate reproduction of arterial flow waveforms is important for in vitro cardiovascular experiments and controlled biomedical flow platforms. This study characterizes the open-loop dynamics of an AC motor-inverter-centrifugal-pump platform using five experimentally recorded input-output datasets representing femoral, carotid, iliac, coronary, and aortic waveform conditions. The inverter command was the input, the magnetic flow-meter voltage was the output, and all original recordings were sampled at 100 Hz. Vessel-specific FIR, ARX, and ridge-regularized ARX models were screened separately. A common model was selected using nested chronological validation and assessed on untouched test segments using one-step prediction, recursive free-run simulation, and diagnostic analyses. Vessel-specific one-step validation fits ranged from 80.33% to 92.80%. The common ARX(5,4,80) model achieved mean one-step and free-run fits of 95.82% and 80.04%, respectively. All poles were inside the unit circle, but significant residual autocorrelation showed that the measured response was not fully explained. The common model provides a compact nominal representation of the tested platform. Its comparison with vessel-specific models is descriptive because it uses more training data, and cycle consistency within a recording does not establish between-session experimental reproducibility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automatic control of arterial blood pressure: computer, benchtop, and animal models.Frontiers in medical technology · 2026
- Robust Position Control of a Four Phase Linear Switched Reluctance Motor for Precision Drug Infusion: Real Flux Linkage Modelling and Load Disturbance RejectionEngineering Research Express · 2026
- Methodological development of a pneumatic artificial muscle-driven left ventricular simulator using interpretive structural modeling.PloS one · 2026
- A Low-Cost Fourier-Based Dual-Pump Mock Circulatory Loop for Arterial Pressure Waveform Reproduction.Bioengineering (Basel, Switzerland) · 2026
- Hybrid Grey-Box–ARX Identification and Constrained Model Predictive Control of a 250 L Jacketed Batch Milk PasteurizerProcesses · 2026
- Design and experimental validation of a real-time feedback control system for precision row seedingEcological Engineering & Environmental Technology · 2026