Complementing Linear Static Retrofit Design with Pushover Analysis: A Comparative Study of a Four-Story 26-Year-Old RC Building
Benito M. Pacheco, Fernando J. Germar, Eric Augustus J. Tingatinga, Marcus Karl J. Evangelista, Alyannah P. Terite, Gabriel Antonio I. Pimentel
Key points
From the paper's conclusion- This study examines the seismic evaluation and retrofit design of a four-story, 26-year-old reinforced-concrete building, using the linear static procedure (LSP) as the primary approach, complemented by nonlinear static (pushover) analysis in accordance with ASCE 41 provisions, both implemented in a commercially available, industry-grade software.
Abstract
This study examines the seismic evaluation and retrofit design of a four-story, 26-year-old reinforced-concrete building, using the linear static procedure (LSP) as the primary approach, complemented by nonlinear static (pushover) analysis in accordance with ASCE 41 provisions, both implemented in a commercially available, industry-grade software. Initial evaluation using LSP indicates that 55% or 206 of 374 beams and 21% or 48 of 228 columns exceed a demand–capacity ratio of 1.0 and therefore require strengthening. In contrast, pushover analysis of the same unretrofitted structure identifies hinge formation in 6% or 24 of beams and 25% or 57 of columns. Concrete and steel jacketing schemes are designed for the members identified as deficient by LSP. Subsequent pushover analyses of the retrofitted models reveal that five (5) columns in the concrete jacketing scheme and three (3) columns in the steel jacketing scheme exceed the Life Safety performance level. Capacity spectrum analysis per FEMA 440 classifies the concrete-jacketed model within the moderate-damage range, and the steel-jacketed model within the no-damage threshold. Complementing linear static retrofit design with pushover analysis improves the assessment of global behavior, reveals residual inelastic demands, and guides the iterative design process. Use of commercial software could hasten practical applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Numerical Seismic Performance of a Beam–Column Connection in Hospital RC Buildings Retrofitted with Dissipative Bracing: Implications for Behaviour Factor EvaluationApplied Sciences · 2026
- Seismic Retrofit Strategy Selection and Prioritisation for Existing RC Road BridgesInfrastructures · 2026
- From code to performance: Probabilistic seismic response of retrofitted precast RC buildingsEngineering Structures · 2026
- Comparative Seismic Performance of Hybrid Reinforced Concrete–Masonry Buildings Retrofitted with Different Strengthening Systems: A Nonlinear Finite Element StudyBuildings · 2026
- Experimental Investigation and Displacement‐Based Seismic Design of Dual‐Column Tall Bents Retrofitted With Novel Repairable Double‐Stage Capacity‐Adjustable BRBsEarthquake Engineering & Structural Dynamics · 2026
- Numerical Investigation of Retrofitting Strategies for Existing Reinforced Concrete Beam-Column Joints: A Systematic ReviewInternational Journal for Research in Applied Science and Engineering Technology · 2026