Experimental Investigation and Displacement‐Based Seismic Design of Dual‐Column Tall Bents Retrofitted With Novel Repairable Double‐Stage Capacity‐Adjustable BRBs
Liang Cai, Kaiqi Lin, Darong Wang, Zhe Qu, Weidong Zhuo
Key points
From the paper's conclusion- The results show that the proposed method achieves the target double‐stage seismic performance.
Abstract
To enhance the seismic resilience and post‐earthquake repairability of reinforced concrete (RC) dual‐column tall bents under multilevel seismic hazards, an RC dual‐column tall bent (DCTB) system retrofitted with modularized all‐steel assembled double‐stage capacity‐adjustable buckling‐restrained braces (MAS‐CABRB), termed MCABRB‐DCTB, is proposed. By incorporating the double‐stage force characteristic and repairability of the MAS‑CABRB, this system enables multilevel seismic‑performance regulation and rapid post‑earthquake recovery. A series of 1/8‐scale MAS‐CABRB component and MCABRB‐DCTB specimens were tested under quasi‐static cyclic loading to investigate their hysteretic behavior, double‐stage mechanisms, and repairability. The results indicate that both specimens exhibited stable hysteretic responses and clear double‐stage characteristics. The performance of the MAS‐CABRB component and the MCABRB‐DCTB system can be readily restored by simply replacing the damaged sacrificial plates. Building upon the tests, a theoretical model of the MCABRB‐DCTB system was established to derive the stiffness and strength formulations, and a corresponding displacement‐based double‐stage seismic design method was then proposed. A 40‐m‐height prototype bridge bent was designed following the proposed method and validated through nonlinear time‑history analysis. The results show that the proposed method achieves the target double‐stage seismic performance. Under E1‐level earthquakes, the system maintains high lateral stiffness and effectively regulates the structural deformation. Under E2‐level earthquakes, the controlled strength degradation of the MAS‐CABRB concentrates energy dissipation within the braces and significantly reduces pier column damage and pier‐base force demands.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dynamic Behavior of Uplift‐Rocking Tall Bridge Bent Systems: Theoretical Modeling, Verification, and Dimensionless AnalysisEarthquake Engineering & Structural Dynamics · 2026
- Evaluation of seismic behaviour of strongback brace system with buckling restrained braceProceedings of the Institution of Civil Engineers - Structures and Buildings · 2026
- Self-Centering Energy Dissipative Braces for Seismic Resilience: Evolution, Mechanical Behavior, Experimental Validation, and Engineering ApplicationsBuildings · 2026
- Seismic Performance and External Span-Width Optimization of Reinforced Concrete Frames Retrofitted with RP-FD-BRBsBuildings · 2026
- Numerical Seismic Performance of a Beam–Column Connection in Hospital RC Buildings Retrofitted with Dissipative Bracing: Implications for Behaviour Factor EvaluationApplied Sciences · 2026
- Experimental investigation of seismic performance of reinforced concrete beam‐column joints with hybrid connections combining friction side plates and composite energy‐dissipation boxesStructural Concrete · 2026