Monitoring antiproton numbers with a CMOS detector in a dense-track environment
C. Regenfus, P. Adrich, I. Belosevic, F. Benkel, M. Chung, P. Cladé, P. Comini, P. Crivelli,
Key points
From the paper's conclusion- We have used a commercial CMOS digital camera mounted around the experimental vacuum chamber to determine antiproton numbers from ionising particles created in the annihilation process on the surface of microchannel plate detectors which are used for beam imaging.
Abstract
The production of antihydrogen by the GBAR experiment at AD/ELENA requires good knowledge of the number of incident keV antiprotons, which can be problematic. We have used a commercial CMOS digital camera mounted around the experimental vacuum chamber to determine antiproton numbers from ionising particles created in the annihilation process on the surface of microchannel plate detectors which are used for beam imaging. We show that the multiplicity of emerging charged particles is as expected for individual annihilations of antiprotons with nucleons at rest, taking into account the surrounding material budget. Most of those particles are in the minimal ionising regime, but can be detected with nearly 100% efficiency in the CMOS pixel detector, while due to the thin depletion layer the device is insensitive to background gammas. Thanks to the high granularity and small pixel size millions of antiproton annihilations can be reconstructed in a dense tracking environment over a large dynamic range with good resolution. From cluster length studies of non perpendicular tracks the thickness of the depletion zone and effective detection area was estimated. The cluster length also allows for a monitoring of track angles. Antiproton numbers are determined from the number of reconstructed clusters in the CMOS sensor by means of the covered solid angle relative to a calibration measurements with well known beam intensities at the most upstream location of the GBAR apparatus. Material effects on the emerging annihilation products were estimated by Monte Carlo ( GEANT4 ) calculations, while annihilation artefacts on the complex surface of a microchannel plate are cancelled out in this approach. This method minimises largely systematic uncertainties, leading to a final error of roughly 10% for the reconstruction of absolute antiproton numbers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A determination of the backscattering probability of low-energy antiprotons.The European physical journal. C, Particles and fields · 2026
- High-Statistics Study of Antiproton Annihilation at Rest on Argon in a LArTPCarXiv · 2026
- Design, Testing and Calibration of the GAPS Experiment Si(Li) Tracker Readout ASIC: From the First Flight Campaign Toward the Second Mission UpgradearXiv · 2026
- Charge collection parameterization of MALTA2, a depleted monolithic active pixel sensorJournal of Instrumentation · 2026
- Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detectorPhysical review. D/Physical review. D. · 2026
- High-rate accumulation of ${8.9\times10^9}$ positrons using a linac-driven buffer-gas trap combined with a SiC remoderatorarXiv · 2026