Design and parametric modal optimization of a low-vibration liquid-helium cryostat for a cryogenic current comparator
Jie Xie, Haiming Shao, Weibin Xi, Jipeng Fan, Qingqing Du, Changdong He
Key points
From the paper's conclusion- To meet the requirements of cryogenic current comparators (CCCs) for stable cryogenic operation in precision large direct current measurement, a low-heat-load and low-vibration liquid-helium cryostat with an external helium reliquefier was designed and optimized.
Abstract
To meet the requirements of cryogenic current comparators (CCCs) for stable cryogenic operation in precision large direct current measurement, a low-heat-load and low-vibration liquid-helium cryostat with an external helium reliquefier was designed and optimized. The cryostat provides a 4.2 K liquid-helium bath for the CCC. To reduce disturbances from the installation environment and reliquefier, a strategy combining global low-frequency isolation and internal high-frequency vibration avoidance was adopted. The isolation layer lowers the low-order modal frequencies of the global system, while enhanced support stiffness shifts internal modes away from the main disturbance bands. Based on the available cooling capacity and measured site vibration spectra, the design criteria were defined as a 4.2 K heat load below 0.54 W, global low-order modal frequencies below 20 Hz, and an internal control modal frequency above 50 Hz. A heat-load model for the 4.2 K stage and a thermally constrained modal design window were established. With lower axial and vertical support diameters of 12 mm and 10 mm, the 4.2 K heat load is 0.53 W, and the first horizontal and vertical modal frequencies are 59.55 Hz and 69.5 Hz. With the isolation layer, the first resonance peaks in three directions are 9.7 Hz, 9.5 Hz, and 14.7 Hz. Under measured floor excitation, the one-third-octave root-mean-square velocities at the CCC remain below the Vibration Criterion C limit of 12.5 μm/s. Strength and buckling evaluations confirm sufficient safety margins under normal and fault conditions. The results provide useful design data for high-precision CCC cryostats.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Acoustic damping limits superfluid helium as a thermal bath for mechanical resonatorsarXiv · 2026
- Supercritical Helium Flow Calorimetry at the MIT Superconducting Magnet Test FacilityHarvard Dataverse · 2026
- Design of a high-stability soft-sealed cryogenic vibration coupled system for vibration sensor calibration (20 K-298 K)Measurement Science and Technology · 2026
- Low power conduction-cooled superconducting rectifier with >100 A output for 1.1 W cryogenic heat loadSuperconductor Science and Technology · 2026
- An integrated low-friction low-resonance passive vibration isolator: tunable nonlinear stiffness, damping, and inertiaNonlinear Dynamics · 2026
- High-resolution calorimetric sample platforms for cryogenic thermodynamic studies with multimodal synchrotron x-ray compatibility.The Review of scientific instruments · 2026