Low power conduction-cooled superconducting rectifier with >100 A output for 1.1 W cryogenic heat load
Adam Carl Francis, Ryan Moore Galloway, Nick Rogers-Rehn, Sebastian Oberbauer, Donald Pooke, Rod Badcock, Dominic Ashley Moseley
Key points
From the paper's conclusion- These quantities provide useful diagnostics for rectifier performance and load-coil health, and identify waveform optimization as a route to improve useful rectification power while maintaining a low cryogenic heat load.
Abstract
A conduction-cooled superconducting half-wave transformer rectifier is presented that supplies more than 100 A to a superconducting load with an estimated total cryogenic heat load of 1.1 W operating at 79K. The origins of loss in the system are analysed using a cycle-averaged power metric, allowing the ohmic losses of coils, current-lead heat leak, superconducting switch dissipation, and joint losses to be evaluated separately. This approach shows that the dominant heat load arises from the copper windings rather than from the superconducting rectification process. The same cycle-averaged framework is then applied to the directional power delivered to the load coil, separating positive, negative, and net load-power components. These quantities provide useful diagnostics for rectifier performance and load-coil health, and identify waveform optimization as a route to improve useful rectification power while maintaining a low cryogenic heat load. This system was designed for retrofitting into commercial closed-cycle optical cryostats allowing the addition of a ≥1 T magnet into their existing products without significant modification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Supercritical Helium Flow Calorimetry at the MIT Superconducting Magnet Test FacilityHarvard Dataverse · 2026
- Development of a Prototype Superconducting Radio-Frequency Multicell Cavity for Compact, Conduction-Cooled AcceleratorsarXiv · 2026
- Mathematical investigation of regenerator efficiency and thermal penetration depth in pulse tube cryocoolersInternational Journal of Air-Conditioning and Refrigeration · 2026
- Development of a low-level radio frequency system for remote in situ superconducting radio frequency cavity measurements and calibrations in conduction-cooling systemsarXiv · 2026
- Design and parametric modal optimization of a low-vibration liquid-helium cryostat for a cryogenic current comparatorJournal of Instrumentation · 2026
- Design of a 5.6 MW Three-Level Neutral-Point-Clamped Converter for the CRAFT NNBI Power SupplyElectronics · 2026