A Python-based list-mode data acquisition system for legacy CAMAC instrumentation: design, dead-time characterization, and coincidence capability
Pedro Santa Rita, Efraín Chávez, Andrés Álvarez
Key points
From the paper's conclusion- We present an open-source, Python-based data-acquisition system that restores multi-parameter, event-by-event (list-mode) operation to such crates through the W-IE-NE-R CC-USB controller, which executes a programmable command stack autonomously on each trigger.
Abstract
Fully functional CAMAC ADCs, TDCs and logic modules remain in routine service across small accelerator and teaching laboratories long after commercial list-mode readout has become costly or discontinued. We present an open-source, Python-based data-acquisition system that restores multi-parameter, event-by-event (list-mode) operation to such crates through the W-IE-NE-R CC-USB controller, which executes a programmable command stack autonomously on each trigger. The system reads two Phillips Scientific 7164 peak-sensing ADCs and a 7186 TDC, reconstructing every detector firing within a trigger as one correlated record, with a host-driven polled mode as a robust fallback. A pulser sweep gives a linear response (⟨ a ⟩ = 0.984 ± 0.006 channels/mV; integral non-linearity within 2.7 % of full scale). The readout chain is non-paralyzable with a per-event dead time that follows from its configuration, a programmed 200 μs trigger delay in the controller plus gate, conversion and stack execution: periodic pulser drive gives the predicted staircase response with τ = 249(6) μs, and a 137 Cs source at several distances confirms the same value under Poisson arrivals, both in the distribution of inter-event intervals ( τ = 244(13) μs) and in the recorded rates, which the non-paralyzable model reproduces with no free parameter to within 2.6 %. On the same LaBr 3 (Ce) detector the system matches the 137 Cs resolution of a commercial Spectech MCA at 662 keV (4.12 % versus 4.18 %), and an offline 241 Am α-γ coincidence recorded with a mixed triple- α source demonstrates the multi-parameter capability a single MCA cannot provide. The complete software is released openly under the MIT license ( https://doi.org/10.5281/zenodo.19157215 DOI:10.5281/zenodo.19157215 ).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Discrete Amplitude-to-Time Conversion Circuit for TDC-Based Readout of Fast Scintillation DetectorsarXiv · 2026
- Measurements of the micro-spill structure of medical cyclotron and synchrotron beams and its impact on pulse pileupJournal of Instrumentation · 2026
- Run-dependent timing offsets and their correction in digital data acquisition systemsJournal of Instrumentation · 2026
- Experimental validation of the scintiPulses shot-noise model for coincidence resolving-time dependencies in liquid scintillation counting.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Development of a high-granularity, high-precision timing readout electronics system for large-area MRPC detectorsarXiv · 2026
- Development of a system for testing full-size CMS LGAD sensorsJournal of Instrumentation · 2026