Comparison of twin-screw and centrifugal Pumps for engine cooling under Real Driving Conditions
Federico Di Prospero, Marco Di Bartolomeo, Ali Deriszadeh, Davide Di Battista, Roberto Cipollone
Key points
From the paper's conclusion- Under real driving conditions, where engine speed and thermal demand vary continuously, centrifugal pumps almost always operate far from optimal conditions, producing non-negligible energy losses.
Abstract
Engine thermal management represents an effective strategy to significantly reduce CO 2 emissions and pollutant emissions of on-the-road vehicles without requiring substantial modifications to the engine architecture. Beyond combustion optimization and friction reduction, enhancing the efficiency of auxiliary components plays a crucial role in decreasing parasitic losses, so improving organic efficiency and producing an overall vehicle fuel economy (global efficiency increase). Among auxiliaries, the engine coolant pump has a direct impact on engine thermal regulation and energy consumption. Centrifugal pumps are widely adopted as coolant circulation devices due to their mechanical simplicity and reliability. However, their efficiency is strongly dependent on rotational speed which peaks at the design operating point. Under real driving conditions, where engine speed and thermal demand vary continuously, centrifugal pumps almost always operate far from optimal conditions, producing non-negligible energy losses. Conversely, volumetric (positive displacement) pumps are characterized by a flow rate that is directly proportional to rotational speed and by a generally flatter efficiency curve over a broader operating range. The variations with pump speed (i.e. flow rate delivered) are much lower and this feature makes volumetric pumps particularly attractive for automotive applications, considering the inherent typical operation. In this study, a twin-screw positive displacement pump was designed, manufactured, and experimentally characterized for automotive engine cooling applications. Its performance was directly compared with that of a centrifugal pump specifically developed for the same vehicle platform and designed to meet identical cooling requirements. Both pumps were tested on a dynamic coolant pump test bench capable of reproducing different hydraulic circuit conditions. Experimental investigations were carried out by varying rotational speeds and pressure heads, evaluating flow rate delivery, hydraulic performance, and overall efficiency. Subsequently, both pumps were virtually integrated—alternatively—into the same engine cooling circuit of an instrumented vehicle, ensuring comparable boundary conditions and identical thermal constraints. A real-world driving cycle was conducted along a predefined route, during which cooling system operating parameters, including required flow rates and pressure heads, were recorded. Based on this experimental data, the instantaneous power consumption and cumulative energy absorption of both pumps were evaluated. The comparison enabled a quantitative assessment of the energy demand associated with each pump technology under realistic operating conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The performance of engine coolant control strategies on real driving emissionsApplied Thermal Engineering · 2026
- Performance and cavitation in automotive centrifugal pumps: experimental analysis and 3D-CFD modelling assessmentApplied Thermal Engineering · 2025
- An Experimental Study on Energy Saving and Carbon Emission Reduction in a Variable Speed Multistage PumpSustainability · 2026
- Comparative Analysis of Scale Effects on the Flow Characteristics of a Reactor Coolant PumpJournal of Physics: Conference Series · 2026
- A Critical Review of Performance Enhancement Methods for Automotive Air-Conditioning Compressors Using Nano-Enhanced LubricantsMachines · 2026
- Flow Coefficient as a Normalising Operating Parameter for Comparison of Drop-in Fluid Replacement in Centrifugal CompressorsProcesses · 2026