G. Di Cicco, D. Lanni, A. Perna, A. Agresta, M. Della Pietra, V. Cigolotti
Key points
From the paper's conclusion- Overall, the analysis indicates that under the study’s assumptions, ammonia-based hydrogen refueling stations can represent a feasible solution for decentralized hydrogen supply, with large-sized grid-connected configurations showing the best economic attractiveness.
Abstract
Ammonia represents a promising hydrogen carrier for hydrogen refueling stations, especially in situations where direct hydrogen delivery may be logistically complex or economically unfavorable. This study presents a techno-economic assessment of ammonia-based hydrogen refueling stations with on-site hydrogen production through ammonia cracking. Two plant configurations are analyzed: an on-grid layout, where the station electricity demand is supplied by the grid, and an off-grid layout, in which this requirement is met by a PEM fuel cell (PEMFC) unit. These configurations were selected to investigate the influence of different energy supply strategies on station performance and economic viability. Furthermore, two nominal hydrogen production capacities, namely 500 and 1000 kgH 2 /day, are considered to evaluate the effects of plant scale on both technical and economic outcomes. A technical model is developed to determine the component sizes, ammonia consumption and electricity demand. This model also includes the refueling line, consisting of hydrogen compression, dispensing equipment, and a three-cascade storage system. Based on the technical results, an economic assessment is then carried out using a comprehensive set of indicators, including the Levelized Cost of Hydrogen (LCOH), Discounted Payback Period (DPBP), Net Present Value (NPV), and Profitability Index (PI). The results show that increasing the station capacity improves the economic performance in both configurations. The LCOH decreases from 9.55 to 9.18 €/kgH 2 in the off-grid layout and from 7.33 to 7.08 €/kgH 2 in the on-grid layout when moving from 500 to 1000 kgH 2 /day. In terms of investment recovery, the on-grid configuration achieves a discounted payback period of 7 years for both station sizes, compared with 15 and 13 years for the corresponding off-grid cases. Overall, the analysis indicates that under the study’s assumptions, ammonia-based hydrogen refueling stations can represent a feasible solution for decentralized hydrogen supply, with large-sized grid-connected configurations showing the best economic attractiveness.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Sizing, economic analysis and optimisation of green hydrogen refuelling stations in a cluster of small islandsRenewable Energy · 2026
- Techno-economic and environmental comparison of high- and low-pressure ammonia decompositionInternational Journal of Hydrogen Energy · 2026
- Green ammonia: A techno-economic supply chain optimizationJournal of Cleaner Production · 2026
- Techno-Economic Analysis of Low-Temperature Alkaline Ammonia Electrolysis Using a Gross Margin ModelEnergy & Fuels · 2026
- Techno-economic insights into ammonia as a hydrogen vector: synthesis, cracking, storage, and supply chain solutionsGreen Chemistry · 2026
- Techno-economics analysis of green ammonia system under continuous and dynamic operations in semi-islanded systemFuel · 2026