Experimental Study on Dynamic Water Closing of Inlet Ball Valve for High-Head Pumped Storage Power Station
Peng Guo, Wenfu Han, Zaiqiang Wu, Fei Zhang, Lei Deng
Key points
From the paper's conclusion- The Jixi Pumped Storage Power Station features a rated head of up to 600 m, making it a representative high-head pumped-storage facility where reliable dynamic water closing of the inlet ball valve is critical for operational safety.
Abstract
The Jixi Pumped Storage Power Station features a rated head of up to 600 m, making it a representative high-head pumped-storage facility where reliable dynamic water closing of the inlet ball valve is critical for operational safety. To verify that the inlet ball valve of Unit 5 can reliably shut off the full flow of the pump-turbine under dynamic water conditions without closing the guide vanes, and to confirm that no harmful deformation or damage occurs to the ball valve, a series of dynamic water closing tests were conducted under three operating conditions: no-load, 50% rated load, and 100% rated load. Key parameters were comprehensively monitored throughout the tests, including the axial displacement of the ball valve along the water flow direction, hydraulic pressures in the opening and closing chambers of the servomotor, pressure upstream of the ball valve, pressure at the volute inlet and draft tube inlet, as well as vibration of the ball valve body, unit structural vibration, and main shaft run-out. The test results indicate that the ball valve closing times under the three operating conditions were 59.6 s/100%, 59.3 s/100%, and 58.4 s/100%, respectively, demonstrating stable closing performance. The maximum axial displacements of the ball valve under 50% and 100% load conditions were 0.37 mm and 0.81 mm, respectively, both within the allowable limits. Under all load conditions, pressure indicators satisfied the regulation guarantee requirements, and the broadband amplitudes of pressure pulsation, vibration, and shaft run-out remained within controllable ranges. Post-test inspection confirmed that no harmful deformation or damage was sustained by the ball valve. This study validates the dynamic water closing performance of the inlet ball valve at Jixi Pumped Storage Power Station and provides a valuable reference for similar dynamic water closing tests at other high-head pumped-storage facilities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Investigations on the influence of valve closing rules on transient flow characteristics in pressurized pipelinesJournal of Physics: Conference Series · 2026
- Research on start-up transition process of high-head pumped storage unitsFrontiers in Mechanical Engineering · 2026
- Transient hydrodynamic instability during the rapid closing process of the guide vanes of pump turbines under power generation conditionsProceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · 2026
- Design, implementation and validation of a web-based dynamic simulation platform for pumped storage hydropower plant control systems.PloS one · 2026
- Simulation Analysis of the Dynamic Characteristics of the High-Speed Unloading Valve in the Back Pressure Assembly of an Injector Test System and Unloading Testing of the ValveActuators · 2026
- Numerical Investigation of Internal Flow Characteristics in a Variable-Speed Pumped Storage Power Plant During Load Rejection with Guide Vane Closing FailureSymmetry · 2026