Comparative study on the thermodynamic performance of R32 and R290 rotary compressors considering refrigerant injection and actual operation boundaries
Junhong Wu, Shu Zhang, Qijian Sun, Xi Pan, Junlong Xie
Key points
From the paper's conclusion- The results reveal that the limitation of R32 rotary compressor is the high discharge temperature but the limitation of R290 rotary compressor is the low discharge superheat degree.
Abstract
This paper presents a comparative study on the thermodynamic performance of R32 and R290 rotary compressors in a vapor compression refrigeration system with refrigerant injection. The thermodynamic performance evaluation of R32 and R290 rotary compressor are from six perspectives including power consumption, cooling capacity, COP, suction mass flow rate, discharge temperature and discharge superheat degree. A mathematical model is developed to simulate these parameters, with the optimization of cycle performance primarily achieved through the control of suction superheat degree, injection superheat degree and injection pressure. The results reveal that the limitation of R32 rotary compressor is the high discharge temperature but the limitation of R290 rotary compressor is the low discharge superheat degree. For R32, the saturated refrigerant injection is benefit at most working conditions. And the optimal COP can be obtained by controlling the suction superheat degree firstly, following by controlling the injection pressure and injection superheat degree. For 290, the saturated refrigerant injection is not applicable. The suction superheat degree and the injection temperature should be as large as possible within the boundary. The optimal COP can be obtained by further increasing the injection pressure until the discharge superheat degree drops to the boundary temperature. However, when discharge superheat degree is lower than the boundary temperature, the refrigerant injection is not used to avoid decreasing the discharge superheat degree. By controlling operation parameters to the unique properties of R32 and R290, it is possible to enhance system efficiency and reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Thermodynamic analysis of a dual-nozzle ejector enhanced refrigeration cycle for domestic refrigerator/freezer applicationApplied Thermal Engineering · 2026
- Experimental evaluation of a R290 vapour compression refrigeration system hybridised with a thermoelectric subcoolerEnergy Conversion and Management · 2026
- Physics-Guided Bioinspired Multi-Objective Optimization for Explainable Drying-Stage Identification in an R290/R600a Waste-Heat Drying System.Biomimetics (Basel, Switzerland) · 2026
- Energy, exergy, and environmental analysis of five low-GWP refrigerants considered as alternatives to R410A for air conditioning systemsInternational Journal of Air-Conditioning and Refrigeration · 2025
- Assessment of key performance indicators for a reciprocating compressor with electronically controlled vapor injectionApplied Thermal Engineering · 2026
- Systematic review of exergy performance in natural refrigerant cycles with internal heat exchangersFrontiers in Thermal Engineering · 2026