Journal of Physics: Conference Series

Transient dynamics of rotor-stall-induced water hammer in helical axial-flow multiphase pump systems

Yingjian Hao, Wei Han, Rennian Li

Key points

From the paper's conclusion
  • To elucidate the influence of impeller rotational speed on the transient characteristics of rotor sticking in a helical axial-flow oil–gas multiphase pump, an unsteady numerical model of a closed pump system was developed, and the numerical approach was validated against experimental results.

Abstract

To elucidate the influence of impeller rotational speed on the transient characteristics of rotor sticking in a helical axial-flow oil–gas multiphase pump, an unsteady numerical model of a closed pump system was developed, and the numerical approach was validated against experimental results. By analyzing the variations in head, torque, flow rate, and pressure during rotor sticking under different initial rotational speeds, the results indicate that: After rotor sticking occurs, the system energy input is abruptly interrupted. Both head and torque decrease rapidly and may become negative, the inlet and outlet flow rates significantly decay, and pressure exhibits severe fluctuations with typical water hammer characteristics. With increasing initial rotational speed, the negative peak of head, the magnitude of negative torque, and the intensity of pressure fluctuations all increase significantly, indicating that rotor sticking under high-speed conditions induces stronger transient impacts and more pronounced flow instability. This study provides a useful reference for the prediction and safety protection of rotor sticking accidents in deep-sea oil–gas multiphase pumps.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers