Journal of Physics: Conference Series

Characteristics of Rotating Stall and Pressure Pulsation in a Solid-Liquid Two-Phase Centrifugal Pump at Low Flow Rates Based on CFD-DEM Two-Way Coupling

Yuting Jiang, Yi Li, Yonglong Jiang

Key points

From the paper's conclusion
  • Overall, this study provides a direct reference for analyzing pressure pulsations and assessing low-frequency vibration risks in solid-liquid centrifugal pumps at low flow rates.

Abstract

Centrifugal pumps often experience rotating stall and flow separation at low flow rates. This causes significant pressure pulsations and unit vibration. In solid-liquid two-phase flows, the effect of particle size on this unsteady stall behavior remains unclear. To investigate this, we simulated the 3D unsteady flow in a three-blade centrifugal pump at a low flow rate of 0.2 Q . The simulation used a two-way coupled CFD-DEM model. The particle volume fraction was fixed at 5%, with tested particle diameters ( d p ) of 2, 3, and 4 mm. We analyzed static pressure distributions, streamlines, relative velocity vectors, and pressure spectra to determine how particle size and Stokes number ( St ) affect rotating stall and pressure pulsations. Results show a low-pressure backflow zone and asymmetric flow structures inside the impeller at 0.2 Q . Adding particles changes the position and shape of the backflow vortex. As the particle size increases, the low-pressure boundary, vortex core, and low-velocity regions shift accordingly. With 4 mm particles, the local backflow vortex loses continuity. Furthermore, irregular flow separation appears in some blade channels. The pressure pulsation intensity is spatially uneven. Inside the impeller, the root-mean-square pressure coefficient ( C p-RMS ) increases along the flow direction. Pulsation levels are highest near the volute tongue. In this tongue region, the C p-RMS changes non-monotonically with particle size. It decreases for the 3 mm particles but rises again for the 4 mm particles. Frequency-domain analysis shows that the blade passing frequency (3 f n ) dominates pressure pulsations at monitoring points CP3 and VC1. Harmonics such as 6 f n and 9 f n are also present. At 3 f n , the 2 mm particle case produces the highest amplitudes at both points. When the particle diameter increases to 3 mm and 4 mm, these dominant amplitudes decrease. In the low-frequency range, the characteristic stall frequencies at CP1 and VC1 are 0.35 f n , 0.70 f n , and 0.18 f n corresponding to St values of 2.20, 4.94, and 8.78, respectively. This indicates a distinct non-monotonic trend. Overall, this study provides a direct reference for analyzing pressure pulsations and assessing low-frequency vibration risks in solid-liquid centrifugal pumps at low flow rates.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers