Effects of solids mass flow rate and aeration on pressure-load distribution in an FCC regenerated-catalyst standpipe
Chaoqun Wang, Chaoyu Yan
Key points
From the paper's conclusion- An Eulerian–Eulerian two-fluid model was evaluated against standpipe measurements and then applied to 16 combinations of solids mass flow rate (5-20 kg s −1 ) and superficial aeration velocity (0-0.42 m s −1 ).
Abstract
Gravity-driven catalyst flow, aeration, and butterfly-valve throttling jointly determine the axial pressure load in an FCC regenerated-catalyst standpipe. An Eulerian–Eulerian two-fluid model was evaluated against standpipe measurements and then applied to 16 combinations of solids mass flow rate (5-20 kg s −1 ) and superficial aeration velocity (0-0.42 m s −1 ). Direct comparison showed that the measured inclined-section gauge pressure increased from 1.853 to 3.114 kPa, whereas the calculated valve-upstream pressure increased from 2.128 to 4.245 kPa. The mean bias error and root-mean-square error were 0.802 and 0.869 kPa, respectively; after min–max normalization, r = 0.976, R 2 1:1 = 0.906, and NRMSE = 0.115. Thus, the model exhibited a systematic positive pressure bias but reproduced the response to aeration. The phase contours showed that bend-induced flow redistribution formed a solids-rich band along the lower wall of the inclined pipe and a gas-rich passage near the upper wall. Aeration reduced the magnitude of the negative pressure at the inlet and bend while increasing the positive pressure upstream of the valve. Across all solids throughputs, aeration increased the valve-upstream-to-outlet pressure difference Δp vo = P4 – P3, even when the valve-upstream-to-inlet pressure difference Δp vi = P4 – P1 decreased at low or intermediate throughput. This opposing response shows that the pressure load was progressively transferred toward the valve region. At G s = 10 kg s −1 , raising u a from 0 to 0.42 m s −1 reduced the absolute inlet negative pressure by 64.9% but increased the valve-upstream pressure by 133.2%. Aeration therefore redistributes, rather than uniformly reduces, the standpipe pressure load.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Regulating Gas–Solid Fluidization in a Diameter-Transformed Dense Bed with Geldart A ParticlesACS Engineering Au · 2026
- Computational fluid dynamics modeling of catalyst fluidization in the industrial fluid catalytic cracking regeneratorInternational Journal of Chemical Reactor Engineering · 2026
- Numerical analysis of hydrodynamics in conical spouted bed reactorsPhysics of Fluids · 2026
- Mass conductance of a low pressure LPG injector as a function of valve lift and nozzle diameterJournal of Physics: Conference Series · 2026
- Geometry-dependent gas–liquid transport, pressure pulsation, and energy dissipation in a π-shaped ultrasonic-flowmeter conduitPhysics of Fluids · 2026
- Pressure Drops for Turbulent Liquid Single-Phase and Gas–Liquid Two-Phase Flows in Komax Triple Action Static MixerFluids · 2025