Geometry-dependent gas–liquid transport, pressure pulsation, and energy dissipation in a π-shaped ultrasonic-flowmeter conduit

Zhipeng Li, Deyou Li, Jun Long, Jintao Liu

Computational

Key points

From the paper's conclusion
  • The separate effects of bend angle and pipe diameter on gas–liquid interfacial evolution, cross-sectional void fraction statistics, pressure pulsation spectra, and irreversible energy dissipation were investigated to clarify geometry-dependent transport mechanisms.

Abstract

Gas–liquid two-phase flow in ultrasonic-flowmeter conduits can lead to bubble retention, non-uniform phase distribution, and unsteady pressure fluctuations, which complicate stable transport and ultrasonic measurement. In this study, unsteady numerical simulations were performed for a π-shaped ultrasonic-flowmeter conduit using the Mixture multiphase-flow model, with the predicted interfacial evolution qualitatively assessed against pipe-flow experiments. The separate effects of bend angle and pipe diameter on gas–liquid interfacial evolution, cross-sectional void fraction statistics, pressure pulsation spectra, and irreversible energy dissipation were investigated to clarify geometry-dependent transport mechanisms. The results reveal a nonmonotonic transition in the dominant instability mechanism. At small bend angles, abrupt flow redirection promotes centrifugal separation, local vortical motion, gas retention, and broadband high-frequency pressure pulsations. Increasing the bend angle weakens these disturbances, whereas excessively large angles promote downstream gas coalescence and the re-emergence of narrowband periodic pulsations. Among the investigated bend-angle cases, the 135° configuration yields the lowest total energy loss and inlet-to-outlet pressure drop, whereas the 120° configuration provides a more favorable balance among reduced gas retention, concentrated void fraction distributions, and weakened pressure pulsations. Increasing pipe diameter reduces the overall pressure drop but weakens liquid-phase entrainment and promotes larger gas structures and secondary coalescence; among the investigated diameter cases, 10 mm provides a favorable overall balance. Turbulent dissipation is the dominant loss mechanism, accounting for approximately 86% of the total irreversible energy loss. Within the investigated ranges, a bend angle of 120° and a pipe diameter of 10 mm, respectively, exhibit favorable hydrodynamic performance in the separate angle and diameter assessments, providing a hydrodynamic basis for ultrasonic-flowmeter conduit design under gas–liquid two-phase conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Geometry-dependent gas–liquid transport, pressure pulsation, and energy dissipation in a π-shaped ultrasonic-flowmeter conduit — Science Skim