Journal of Physics: Conference Series

Experimental and analytical fatigue assessment of preloaded M20 and M24 high-strength bolt assemblies with blackened and Dacromet-coated surfaces

Meng Hu, Xiaonong Guo

Key points

From the paper's conclusion
  • A local strain-life assessment based on an axisymmetric finite element model reproduces the failure location and the endurance limit, yet underestimates the crack initiation life; the deviation is traced chiefly to the strain-life curve derived from incremental step tests, and recalculation with a constant-amplitude curve raises the predicted lives in the finite-life range to about 0.7 of the meas

Abstract

High-strength bolts below M36 are widely used in the flange connections of smaller turbines, in tower internals and in numerous other preloaded joints, but the available fatigue data at representative preload levels are largely confined to large diameters, and the fatigue penalty of zinc-flake coatings has not been quantified at this mean stress level. This paper reports constant-amplitude fatigue tests on complete M20 and M24 assemblies of quenched-and-tempered 42CrMo steel, cycled at a nominal mean stress of 630 N/mm 2 , corresponding to the preload level of HV connections. S-N curves for three survival probabilities were established by the staircase and horizon methods. The Dacromet coating reduces the median endurance limit by 42%, about twice the penalty reported for hot-dip galvanizing, whereas increasing the diameter from M20 to M24 changes it by only 3.9%, less than the experimental scatter. Detail category 50 of EN 1993-1-9 remains safe for the blackened series with margins above 2.0, but the margin of the coated series drops to 1.24–1.36. A local strain-life assessment based on an axisymmetric finite element model reproduces the failure location and the endurance limit, yet underestimates the crack initiation life; the deviation is traced chiefly to the strain-life curve derived from incremental step tests, and recalculation with a constant-amplitude curve raises the predicted lives in the finite-life range to about 0.7 of the measured values.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Experimental and analytical fatigue assessment of preloaded M20 and M24 high-strength bolt assemblies with blackened and Dacromet-coated surfaces — Science Skim