From the paper's conclusion
  • Through order analysis, shaft orbit analysis, angle domain analysis, and frequency response characteristic investigation, the main causes of excessive fan bearing housing vibration were identified.

Abstract

This paper addresses the problem of excessive vibration and alarm shutdown of a large fan at the production operating speed of 585 rpm. Through order analysis, shaft orbit analysis, angle domain analysis, and frequency response characteristic investigation, the main causes of excessive fan bearing housing vibration were identified. The study found that the excitation source exhibits significant excitation at the 2nd order and its harmonic orders, triggering resonance in multiple components at 585 rpm, resulting in excessive vibration. Coupling misalignment and motor rotor stiffness asymmetry are the main causes of the 2nd order and its harmonic order vibration at the fan bearing housing. At 585 rpm, the natural frequencies of multiple components are close to the excitation frequencies, especially at 19.5 Hz and 78 Hz, where multiple components have natural frequencies, triggering system resonance and causing a sudden increase in bearing housing vibration. By adjusting the coupling alignment on-site, the fan bearing housing vibration was reduced by 28%, falling below the safe production limit, verifying the effectiveness of the identification and analysis method and rectification scheme for excessive vibration problems caused by multiple overlapping factors in engineering practice.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers