Engineering Research Express

Vibration Diagnosis of a Compound Bearing Fault in a Locomotive Traction Fan Motor Based on Dismantling-Verified Ground Truth and a Data-Integrity Audit

Xueming Luo, Shuai Ye, Jianghong Yu

Key points

From the paper's conclusion
  • A HXD1C locomotive traction fan motor with excessive vibration under rated speed is diagnosed from front-and rear-end return-test records against dismantling-verified findings: the front-end bearing showed grease leakage, carbonization and stiff rotation (wear), while the rear-end outer ring suffered severe creep (fretting) corrosion yet rotated freely.

Abstract

A HXD1C locomotive traction fan motor with excessive vibration under rated speed is diagnosed from front-and rear-end return-test records against dismantling-verified findings: the front-end bearing showed grease leakage, carbonization and stiff rotation (wear), while the rear-end outer ring suffered severe creep (fretting) corrosion yet rotated freely. Because segment gains were inconsistent, a data-integrity audit was performed first; time-domain indices, shaft-frequencynormalized spectra and resonant envelope spectra were then computed only on clean, unclipped segments and compared with theoretical 6310 frequencies. High-gain segments showed positive-direction clipping near full scale, inflating the apparent rear-end kurtosis to 38-67; after excluding them, clean-segment kurtosis dropped to 3.0-3.8, showing the apparent impulsiveness to be an acquisition artifact. Front-end clean segments were energetic and rich in low-order shaft harmonics, matching distributed lubrication/wear damage, whereas rear-end clean segments were flat broadband random vibration with no shaft-harmonic or bearing pass-frequency chain. The 6310 outer-race, inner-race and rolling-element frequencies lie within 0.9-1.6 Hz of the 3rd, 5th and 2nd shaft harmonics-indistinguishable at 1 s/1 Hz resolution-and, combined with non-impulsive creep, make the rear-end damage easily missed by conventional envelope analysis. The case exposes two field pitfalls (range-limited kurtosis artifacts; faultfrequency/shaft-harmonic coincidence) and motivates range headroom, clipping quality gates, longer records with a keyphasor or tacholess order tracking. Conclusions are limited to a single unit under one operating condition.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Vibration Diagnosis of a Compound Bearing Fault in a Locomotive Traction Fan Motor Based on Dismantling-Verified Ground Truth and a Data-Integrity Audit — Science Skim