Journal of Physics: Conference Series

Strain–acoustic-emission fatigue monitoring and graded assessment of tubular joints in long-span steel roofs under variable-amplitude wind loading

Zhuoliang Yu

Key points

From the paper's conclusion
  • Based on a 96 m tubular-truss roof, 20 wind-response histories were condensed into an eight-level loading spectrum, and 12 Q355B CHS–CHS T-joints were tested under constant- and variable-amplitude loading with synchronized strain and acoustic-emission monitoring.

Abstract

Circular hollow-section joints in long-span steel roofs are vulnerable to fatigue cracking under wind-induced variable-amplitude loading. Based on a 96 m tubular-truss roof, 20 wind-response histories were condensed into an eight-level loading spectrum, and 12 Q355B CHS–CHS T-joints were tested under constant- and variable-amplitude loading with synchronized strain and acoustic-emission monitoring. Hot-spot stress and Miner damage quantified fatigue consumption, while rolling prefix-only PELT detected persistent acoustic-emission changes without future information. The calculated and measured saddle stress concentration factors were 5.65 and 5.52. The variable-amplitude specimens reached a mean life of 527,667 cycles and failed at D M ≈ 0.92. The acoustic-emission alarm occurred at 62.2% of fatigue life, preceding surface microcrack initiation by 2.8% of total life. On six independent validation specimens, the fused method achieved a warning-and-critical recall of 0.94, a false-alarm rate of 4.2%, a Macro-F1 of 0.91, and a fatigue-life MAPE of 6.3%.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers