Influence of non-coaxial structures on broadband impedance spectrum detection of high-voltage cable systems
Bangle He, Yunjie Zhou, Jiawei Chen, Hai Li, Yihan Zhou
Key points
From the paper's conclusion- Therefore, when BIS is used for condition assessment of high-voltage cable systems, the spectral variations caused by the test-loop configuration should be identified before judging whether an abnormality exists in the cable body or accessories.
Abstract
Broadband impedance spectrum (BIS) detection can be used for condition assessment of high-voltage cable systems. However, the obtained results are related not only to the cable body and accessories but also to the configuration of the test loop. In this paper, BIS measurements were carried out on a high-voltage cable system before and after the type test. The effects of non-coaxial connections at the testing terminal, grounding leads of the metallic shields at cable joints, and insulation transition regions on the detection results were analyzed. The analysis was based on the transmission response at different frequencies, the detected positions of cable accessories, and the impedance distribution waveforms. The results show that BIS can identify the main accessories in the detection loop, although certain location deviations appear near the GIS termination and adjacent joint. The non-coaxial structure at the connection between the terminal bushing and the output line, the grounding leads of the metallic shields, and the gas-solid insulation transition regions may cause impedance mismatch, signal attenuation, enhanced reflection, and coupling effects. Therefore, when BIS is used for condition assessment of high-voltage cable systems, the spectral variations caused by the test-loop configuration should be identified before judging whether an abnormality exists in the cable body or accessories.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Research on cable condition evaluation method based on multi-sensor information fusionAIP Advances · 2026
- Flexible UHF Antenna Sensor for Partial Discharge Detection of High-Voltage Cable JointsMeasurement Science and Technology · 2026
- Evolutionary Characteristics of Interfacial Defects Inside Vehicle-Mounted High-Voltage Cable Termination for High-Speed TrainsCSEE Journal of Power and Energy Systems · 2026
- Bypass Sheath Voltage Limiters at Cable-to-GIS Terminations: Geometry-Resolved Connection-Lead Impedance for Insulation Coordination Under Very Fast Transient OvervoltagesEnergies · 2026
- Bolt Loosening Detection Techniques for Transmission Tower Member Systems: Framework, Trends, and ChallengesEnergies · 2026
- Evaluation of Distributed Acoustic Sensing (DAS) Systems with Polarization Diversity for Railway Infrastructure: Effects of Fiber Type and Installation Conditions on System Performance.Sensors (Basel, Switzerland) · 2026