  • With a damping ratio of 0.5, the horizontal offset of the load center of mass only affects the measurement zero offset and does not impair the measurement performance of the thrust stand, as long as the offset remains within 1.6 mm.

Abstract

In accordance with the indirect measurement method, a highly integrated inverted pendulum-type thrust stand is designed. The stiffness characteristics and stability conditions of the stand are obtained through free-body diagram analysis. By adjusting the counterweight position, the measurement range is extended from mN to N. With a damping ratio of 0.5, the horizontal offset of the load center of mass only affects the measurement zero offset and does not impair the measurement performance of the thrust stand, as long as the offset remains within 1.6 mm.