A Removable Mechanical Interface for Non-Invasive Strain Measurement in Paddle Shafts: Iterative Design and Experimental Characterization.
Maria I Cruz, Beatriz B Gomes, Marco Silva, Ana M Amaro, Luis Roseiro
CIPER, Faculty of Sport Sciences and Physical Education, University of Coimbra, 3040-248 Coimbra, Portugal. · Coimbra Institute of Engineering, Polytechnic University of Coimbra, 3030-199 Coimbra, Portugal.
Key points
From the paper's conclusion- This study presents the iterative design and characterization of a removable, non-invasive interface for strain measurement on cylindrical paddle shafts, designed for repeated installation without bonding.
Abstract
Accurate force measurement on paddle shafts is essential for performance assessment and technique refinement, yet existing tools typically require permanent shaft modification or recalibration after each utilization. This study presents the iterative design and characterization of a removable, non-invasive interface for strain measurement on cylindrical paddle shafts, designed for repeated installation without bonding. A total of nineteen configurations were developed through an iterative five-phase design process using fused filament fabrication (FFF) and evaluated under static and dynamic laboratory loading, including an exploratory on-water assessment of the distributed-clamping shell with one athlete. Performance was benchmarked against a bonded reference using linearity, hysteresis, repeatability, and signal fidelity. Rigid shells improved linearity but retained high hysteresis, while distributed clamping introduced placement-dependent uncertainty. Beam-based geometries reduced contact sensitivity, and the distal gauge position of an inverted U-shaped beam provided the closest agreement with the reference response under the tested conditions, reaching a coefficient of determination of 0.954-0.990, a mean absolute error of 7.8-17.7 N, and hysteresis of 3.4-9.1% of the applied load range. Its residual hysteresis was concentrated in the low-force unloading region, predominantly near the transition from the propulsive to the recovery phase. No configuration eliminated all trade-offs; acceptable performance depended on the intended measurement context. The resulting framework provides testable design indications for the future development of removable strain-sensing interfaces on cylindrical structures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An Inductive Sensing System for Optimizing Prosthetic Socket Fit.Sensors (Basel, Switzerland) · 2026
- High-Precision Insertion Force Measurements for Cochlear Implant Surgery: Accuracy Analysis of an Improved DeviceCurrent Directions in Biomedical Engineering · 2026
- Hysteresis-free and dynamically resilient strain sensor enabled by interfacial coordinationScience Advances · 2026
- Research on structural optimization and stable grasping control of flexible manipulatorsFrontiers in Mechanical Engineering · 2026
- Validation of a Signal Processing and Sensor Data Fusion Pipeline for Cochlear Implant Insertion Force MeasurementCurrent Directions in Biomedical Engineering · 2026
- Force-Sensor-Integrated Buckle for Wearable Robots.Sensors (Basel, Switzerland) · 2026