Polarization Design and Calibration of AIMS
Junfeng Hou, Yuliang Shen, Liyue Tong, Biyuan Gao, Xiaoming Zhu, Dong-Guang Wang, Jia Ben Lin, Yuanyong Deng,
Key points
From the paper's conclusion- We present the polarization design and calibration of the AIMS telescope.
Abstract
We present the polarization design and calibration of the AIMS telescope. A ffve-mirror optical derotator with negligible instrumental polarization (<0.01%) was designed to replace the traditional K-mirror, the modulation scheme of the Stokes polarimeter was optimized to suppress instrumental polarization. A customized calibration scheme with lock-in ampliffcation was developed to suppress stray-light and reduce the calibration time to 6 minutes per set, with an overall calibration error of 0.05. The calibration results reveal a signiffcant crosstalk (∼ 0.5) between Stokes V and U, which is likely attributable to the dichroic beam splitters. Polarimetric observations of the active region AR 13465 demonstrate the effectiveness of the polarization design and calibration, with the measured Stokes Q/I and V/I proffles showing the expected symmetric and antisymmetric structures. Future work will focus on characterizing the polarization properties of dichroic beam splitters to mitigate this crosstalk.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Considerations for calibration of Stokes polarimeters.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- A Single-Shot Method for the Absolute Polarization Angle Calibration of CMB Telescopes with Artificial Sky Sources via Stellar Diffraction EncodingarXiv · 2026
- The calibration method coupled with registration errors of secondary imaging spectral polarimetric remote sensing systemScientific Reports · 2026
- Error Analysis of the Image Stabilization System for the Xihe-2 Spectral Magnetic TelescopeResearch in Astronomy and Astrophysics · 2026
- Blind calibration of Linear Stokes imaging polarimeter based on trust region expansionJournal of Optics · 2026
- The Simons Observatory: Detector Polarization Angle Calibration Using a Sparse Wire Grid with Initial Datasets of the Small-aperture TelescopesThe Astrophysical Journal Supplement Series · 2026