Research in Astronomy and Astrophysics

Polarization Design and Calibration of AIMS

Junfeng Hou, Yuliang Shen, Liyue Tong, Biyuan Gao, Xiaoming Zhu, Dong-Guang Wang, Jia Ben Lin, Yuanyong Deng,

Key points

From the paper's conclusion
  • We present the polarization design and calibration of the AIMS telescope.

Abstract

We present the polarization design and calibration of the AIMS telescope. A ffve-mirror optical derotator with negligible instrumental polarization (<0.01%) was designed to replace the traditional K-mirror, the modulation scheme of the Stokes polarimeter was optimized to suppress instrumental polarization. A customized calibration scheme with lock-in ampliffcation was developed to suppress stray-light and reduce the calibration time to 6 minutes per set, with an overall calibration error of 0.05. The calibration results reveal a signiffcant crosstalk (∼ 0.5) between Stokes V and U, which is likely attributable to the dichroic beam splitters. Polarimetric observations of the active region AR 13465 demonstrate the effectiveness of the polarization design and calibration, with the measured Stokes Q/I and V/I proffles showing the expected symmetric and antisymmetric structures. Future work will focus on characterizing the polarization properties of dichroic beam splitters to mitigate this crosstalk.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers